Your browser doesn't support javascript.
loading
A new look at an old classic: implementation of a SERS-based water hardness titration.
Duong, Ngoc Mai; Noclain, Angélina; Reichel, Victoria E; de Cordovez, Pierre; Di Meglio, Jean-Marc; Hersen, Pascal; Charron, Gaëlle.
Afiliação
  • Duong NM; Laboratoire Matière et Systèmes Complexes, UMR 7057, Université Paris Cité, CNRS, 10 rue Alice Domon et Léonie Duquet, 75013, Paris, France.
  • Noclain A; Laboratoire Matière et Systèmes Complexes, UMR 7057, Université Paris Cité, CNRS, 10 rue Alice Domon et Léonie Duquet, 75013, Paris, France.
  • Reichel VE; Laboratoire Matière et Systèmes Complexes, UMR 7057, Université Paris Cité, CNRS, 10 rue Alice Domon et Léonie Duquet, 75013, Paris, France.
  • de Cordovez P; Laboratoire Matière et Systèmes Complexes, UMR 7057, Université Paris Cité, CNRS, 10 rue Alice Domon et Léonie Duquet, 75013, Paris, France.
  • Di Meglio JM; Laboratoire Matière et Systèmes Complexes, UMR 7057, Université Paris Cité, CNRS, 10 rue Alice Domon et Léonie Duquet, 75013, Paris, France.
  • Hersen P; Laboratoire Physico Chimie Curie, UMR 168, Institut Curie, Université PSL, Sorbonne Université, CNRS, 75005 Paris, France.
  • Charron G; Laboratoire Matière et Systèmes Complexes, UMR 7057, Université Paris Cité, CNRS, 10 rue Alice Domon et Léonie Duquet, 75013, Paris, France.
Analyst ; 148(15): 3641-3649, 2023 Jul 26.
Article em En | MEDLINE | ID: mdl-37417475
ABSTRACT
The routine use of SERS as an analytical technique has been hindered by practical considerations among which the irreproducibility of its signals and the lack of robustness of its calibration. In the present work, we examine a strategy to perform quantitative SERS without the need for calibration. The method reinvests a colorimetric volumetric titration procedure to determine water hardness but involves monitoring the progression of the titration through the SERS signal of a complexometric indicator. Upon reaching the equivalence between the chelating titrant and the metal analytes, the SERS signal abruptly jumps, which conveniently serves as an end-point marker. Three mineral waters spanning divalent metal concentrations varying by a factor of 25 were successfully titrated in this way, with satisfactory accuracy. Remarkably, the developed procedure can be run in less than an hour, without laboratory-grade carrying capacity and would be relevant for field measurements.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França