Assessing the Novel Myval Balloon-Expandable Valve with the Evolut Valve: A Propensity-Matched Study.
Halim, Jonathan; Rooijakkers, Maxim; den Heijer, Peter; El Haddad, Milad; van den Branden, Ben; Vos, Jeroen; Schölzel, Bas; Meuwissen, Martijn; van Gameren, Menno; El Messaoudi, Saloua; van Royen, Niels; IJsselmuiden, Sander.
Afiliação
  • Halim J; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • Rooijakkers M; Department of Cardiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.
  • den Heijer P; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • El Haddad M; Department of Cardiology, AZ Sint-Jan Brugge, Ruddershove 10, 8000 Bruges, Belgium.
  • van den Branden B; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • Vos J; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • Schölzel B; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • Meuwissen M; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • van Gameren M; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
  • El Messaoudi S; Department of Cardiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.
  • van Royen N; Department of Cardiology, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.
  • IJsselmuiden S; Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
J Clin Med ; 12(13)2023 Jun 22.
Article em En | MEDLINE | ID: mdl-37445248
ABSTRACT

BACKGROUND:

The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve.

METHODS:

In this retrospective single-center study, 223 patients with symptomatic severe aortic stenosis (AS) were included and treated with the Myval BE valve (n = 120) or with the Evolut SE valve (n = 103). Then, 91 pairs were compared after matching. Clinical outcomes were evaluated at 30 days and 1 year. Echocardiographic follow-up was performed at 30 days.

RESULTS:

Procedural complications were rare in both groups. At the 30-day follow-up, no significant difference in cardiac death (Myval 1% vs. Evolut 2%, p = 0.56), stroke (2% vs. 4%, p = 0.41) and myocardial infarction (1% vs. 3%, p = 0.31) was observed. A permanent pacemaker implantation (PPI) was significantly less needed in the Myval group (4% vs. 15%, p = 0.01). At 1 year, cardiac death (2% vs. 4%, p = 0.41) and the stroke rate (7% vs. 5%, p = 0.76) were similar. Moderate-severe paravalvular leakage (PVL) was also comparable in both groups (1% vs. 4%, p = 0.17).

CONCLUSION:

Safety and efficacy outcomes were comparable between the two valves, except for a higher PPI rate for the Evolut SE valve. Up to 1-year follow-up, clinical outcomes showed acceptable rates of stroke and cardiac death with both valves. Valve hemodynamics were excellent with a low rate of moderate-severe PVL in both groups.