Your browser doesn't support javascript.
loading
Gamma radiation effect on the chemical, mechanical and thermal properties of PCL/MCM-48-PVA nanocomposite films.
Vinícius da Silva Paula, Marcos; Araújo de Azevedo, Leandro; Diego de Lima Silva, Ivo; Brito da Silva, Carlos Alberto; Vinhas, Glória Maria; Alves, Severino.
Afiliação
  • Vinícius da Silva Paula M; Faculdade de Engenharia de Materiais, Universidade Federal Do Pará, Ananindeua, 67113-901, Brazil.
  • Araújo de Azevedo L; Laboratório de Terras Raras, Universidade Federal de Pernambuco, Pernambuco 50670-901, Brazil.
  • Diego de Lima Silva I; Departamento de Engenharia Química, Universidade Federal de Pernambuco, Pernambuco 50670-901, Brazil.
  • Brito da Silva CA; Faculdade de Física, Universidade Federal Do Pará, Ananindeua, 67113-901, Brazil.
  • Vinhas GM; Departamento de Engenharia Química, Universidade Federal de Pernambuco, Pernambuco 50670-901, Brazil.
  • Alves S; Laboratório de Terras Raras, Universidade Federal de Pernambuco, Pernambuco 50670-901, Brazil.
Heliyon ; 9(7): e18091, 2023 Jul.
Article em En | MEDLINE | ID: mdl-37483791
ABSTRACT
In this work, poly (vinyl alcohol) (PVA) was employed to produce a Mesoporous Composition of Matter-48 Modified (MCM-48-M or MCM-48-PVA). After surface modification, MCM-48-M was used to produce nanocomposite (NC) films with polycaprolactone (PCL) as a matrix at room temperature. PCL and MCM-48 nanoparticles (NPs) were chosen due to their great biocompatibility and low toxicity. However, MCM-48-M is more compatible with PCL than MCM-48. NC films were sterilized by gamma radiation with a dose of 25 kGy and characterized by experimental techniques to investigate their chemical, mechanical (tensile) and thermal properties. Scanning electron microscopy (SEM) and transmission electronic microscopy (TEM) results indicated that MCM-48-M exhibited a random distribution in the PCL matrix. The PCL chemical structure was preserved in NC films as described by Fourier transform infrared (FT-IR) spectroscopy as well as the tensile and thermal properties of NC films. FT-IR and thermogravimetric analysis (TGA) results showed surface modification. X-ray diffraction (XRD) and differential scanning calorimetry (DSC) showed that crystalline symmetries were preserved and the crystallinity of NC films had small variations in all samples before and after irradiation, respectively. But, our results did not indicate major changes showing that this method is successful for the sterilization of PCL/MCM-48-PVA NC films.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil