Your browser doesn't support javascript.
loading
A Quantitative Detection Algorithm for Multi-Test Line Lateral Flow Immunoassay Applied in Smartphones.
Zhang, Shenglan; Jiang, Xincheng; Lu, Siqi; Yang, Guangtian; Wu, Shaojie; Chen, Liqiang; Pan, Hongcheng.
Afiliação
  • Zhang S; Key Laboratory of Advanced Manufacturing and Automation Technology (Guilin University of Technology), Education Department of Guangxi Zhuang Autonomous Region, Guilin 541006, China.
  • Jiang X; Key Laboratory of Advanced Manufacturing and Automation Technology (Guilin University of Technology), Education Department of Guangxi Zhuang Autonomous Region, Guilin 541006, China.
  • Lu S; School of Information Science and Engineering, Guilin University of Technology, Guilin 541006, China.
  • Yang G; Guangxi Key Laboratory of Electrochemical and Magneto-Chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
  • Wu S; Key Laboratory of Advanced Manufacturing and Automation Technology (Guilin University of Technology), Education Department of Guangxi Zhuang Autonomous Region, Guilin 541006, China.
  • Chen L; Key Laboratory of Advanced Manufacturing and Automation Technology (Guilin University of Technology), Education Department of Guangxi Zhuang Autonomous Region, Guilin 541006, China.
  • Pan H; Guangxi Key Laboratory of Electrochemical and Magneto-Chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
Sensors (Basel) ; 23(14)2023 Jul 14.
Article em En | MEDLINE | ID: mdl-37514695
The traditional lateral flow immunoassay (LFIA) detection method suffers from issues such as unstable detection results and low quantitative accuracy. In this study, we propose a novel multi-test line lateral flow immunoassay quantitative detection method using smartphone-based SAA immunoassay strips. Following the utilization of image processing techniques to extract and analyze the pigments on the immunoassay strips, quantitative analysis of the detection results was conducted. Experimental setups with controlled lighting conditions in a dark box were designed to capture samples using smartphones with different specifications for analysis. The algorithm's sensitivity and robustness were validated by introducing noise to the samples, and the detection performance on immunoassay strips using different algorithms was determined. The experimental results demonstrate that the proposed lateral flow immunoassay quantitative detection method based on image processing techniques achieves an accuracy rate of 94.23% on 260 samples, which is comparable to the traditional methods but with higher stability and lower algorithm complexity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Smartphone Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Smartphone Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China