Your browser doesn't support javascript.
loading
Comparison of outcomes of self-expanding versus balloon-expandable valves for transcatheter aortic valve replacement: a meta-analysis of randomized and propensity-matched studies.
Wang, Baiqiang; Mei, Zeyuan; Ge, Xiao; Li, Yunyi; Zhou, Quan; Meng, Xiao; An, Guipeng.
Afiliação
  • Wang B; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
  • Mei Z; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
  • Ge X; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
  • Li Y; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
  • Zhou Q; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
  • Meng X; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
  • An G; National Key Laboratory for Innovation and Transformation of Luobing Theory; The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, Qilu Hospital of Shandong University, Jinan,
BMC Cardiovasc Disord ; 23(1): 382, 2023 07 31.
Article em En | MEDLINE | ID: mdl-37525092
BACKGROUND: The postoperative outcomes of transcatheter aortic valve replacement (TAVR) with the new generation of self-expanding valves (SEV) and balloon-expandable valves (BEV) remain uncertain. METHODS: We conducted a meta-analysis based on randomized controlled trials (RCTs) and propensity score-matched (PSM) studies to evaluate the performance of the new generation TAVR devices, with a focus on Edwards SAPIEN 3/Ultra BEV, Medtronic Evolut R/PRO SEV, and Boston ACURATE neo SEV. Our primary endpoints were mortality and complications at both 30 days and one year post-operation. RESULTS: A total of 4 RCTs and 14 PSM studies were included. Our findings showed no significant difference between SEV and BEV regarding 30-day and 1-year mortality rates. ACURATE SEV required less permanent pacemaker implantation (PPI) at 30-day as compared to SAPIEN BEV, while Evolut SEV required a higher rate of PPI than SAPIEN BEV. The incidence of stroke, major or life-threatening bleeding (MLTB), major vascular complications (MVC), coronary artery obstruction (CAO) and acute kidney injury (AKI) did not differ significantly between the two groups. SEV had a larger effective orifice area (EOA) and lower mean transvalvular gradients (MPG) compared to BEV. However, there was an increased risk of paravalvular leakage (PVL) associated with SEV. CONCLUSIONS: In terms of 30-day mortality, stroke, bleeding, MVC, AKI, CAO, and one-year mortality, there was comparability between the two valve types following TAVR. SEV was associated with better hemodynamic outcomes, except for a higher incidence of PVL. Compared to SAPIEN BEV, ACURATE SEV had a lower risk of PPI at 30 days, while Evolut SEV was associated with a higher risk of PPI. These findings underscore the importance of personalized valve selection.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Acidente Vascular Cerebral / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Incidence_studies / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: BMC Cardiovasc Disord Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Acidente Vascular Cerebral / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Incidence_studies / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: BMC Cardiovasc Disord Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article