Your browser doesn't support javascript.
loading
Electrical Resynchronization and Clinical Outcomes During Long-Term Follow-Up in Intraventricular Conduction Delay Patients Applied Left Bundle Branch Pacing-Optimized Cardiac Resynchronization Therapy.
Chen, Xueying; Li, Xiao; Bai, Yingnan; Wang, Jingfeng; Qin, Shengmei; Bai, Jin; Wang, Wei; Liang, Yixiu; Chen, Haiyan; Su, Yangang; Ge, Junbo.
Afiliação
  • Chen X; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Li X; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Bai Y; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Wang J; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Qin S; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Bai J; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Wang W; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Liang Y; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Chen H; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Su Y; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
  • Ge J; Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases; National Clinical Research Center for Interventional Medicine, China.
Circ Arrhythm Electrophysiol ; 16(9): e011761, 2023 09.
Article em En | MEDLINE | ID: mdl-37577815
BACKGROUND: Left bundle branch-optimized cardiac resynchronization therapy (LOT-CRT) has shown encouraging results for QRS duration reduction and heart function improvement. However, the feasibility and efficacy of LOT-CRT have not been well established in intraventricular conduction delay patients. This study aims to assess and compare the efficacy and clinical outcome of CRT based on left bundle branch pacing, combined with coronary sinus left ventricular pacing (LOT-CRT) with CRT via biventricular pacing (BiV-CRT) in intraventricular conduction delay patients indicated for CRT. METHODS: Consecutive patients with intraventricular conduction delay and CRT indications were assigned nonrandomized to LOT-CRT (n=30) or BiV-CRT (n=55). Addition of the left bundle branch pacing (or coronary venous) lead was at the discretion of the implanting physician guided by suboptimal paced QRS complex and on clinical grounds. Echocardiographic parameters and clinical characteristics were accessed at baseline and during 2-years' follow-up. RESULTS: Success rate for LOT-CRT and BiV-CRT was 96.8% and 96.4%. LOT-CRT had greater reduction of QRS duration compared with BiV-CRT (42.7±17.4 ms versus 21.9±21.5 ms; P<0.001). Higher left ventricular ejection fraction was also achieved in LOT-CRT than BiV-CRT at 6-month (36.7±9.8% versus 30.5±6.4%; P<0.05), 12-month (34.8±7.6% versus 30.3±6.2%; P<0.05), 18-month (36.3±7.9% versus 28.1±6.6%; P<0.005), and 24-month follow-up (37±9.5% versus 30.5±7%; P<0.05). Adverse clinical outcomes including heart failure rehospitalization and mortality were lower in LOT-CRT group for 24 months follow-up (hazard ratio, 0.33; P=0.035). CONCLUSIONS: LOT-CRT improves ventricular electrical synchrony and may provide greater clinical outcomes as compared with BiV-CRT in intraventricular conduction delay patients. These findings need further evaluation in future randomized controlled trials.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Circ Arrhythm Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Circ Arrhythm Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China