Your browser doesn't support javascript.
loading
Augmented Reality Navigation Plus Indocyanine Green Fluorescence Imaging Can Accurately Guide Laparoscopic Anatomical Segment 8 Resection.
Tao, Haisu; Wang, Zhuangxiong; Zeng, Xiaojun; Hu, Haoyu; Li, Jiang; Lin, Jinyu; Lin, Wenjun; Fang, Chihua; Yang, Jian.
Afiliação
  • Tao H; Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
  • Wang Z; Guangdong Provincial Clinical and Engineering Center of Digital Medicine, Guangzhou, China.
  • Zeng X; Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
  • Hu H; Guangdong Provincial Clinical and Engineering Center of Digital Medicine, Guangzhou, China.
  • Li J; Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
  • Lin J; Guangdong Provincial Clinical and Engineering Center of Digital Medicine, Guangzhou, China.
  • Lin W; Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou, China.
  • Fang C; Guangdong Provincial Clinical and Engineering Center of Digital Medicine, Guangzhou, China.
  • Yang J; The First Affiliated Hospital, College of Medicine, Shihezi University, Shihezi, China.
Ann Surg Oncol ; 30(12): 7373-7383, 2023 Nov.
Article em En | MEDLINE | ID: mdl-37606841
BACKGROUND: Laparoscopic anatomical Segment 8 (S8) resection is a highly challenging hepatectomy. Augmented reality navigation (ARN), which could be combined with indocyanine green (ICG) fluorescence imaging, has been applied in various complex liver resections and may also be applied in laparoscopic anatomical S8 resection. However, no study has explored how to apply ARN plus ICG fluorescence imaging (ARN-FI) in laparoscopic anatomical S8 resection, or explored its accuracy. PATIENTS AND METHODS: This study is a post hoc analysis that included 31 patients undergoing laparoscopic anatomical S8 resection from the clinical NaLLRFI trial, and the resected liver volume was measured in each patient. The perioperative parameters of safety and feasibility, as well as the accuracy analysis outcomes were compared. RESULTS: There were 16 patients in the ARN-FI group and 15 patients underwent conventional laparoscopic hepatectomy without ARN or fluorescence imaging (non-ARN-FI group). There was no significant difference in baseline characteristics between the two groups. Compared with the non-ARN-FI group, the ARN-FI group had lower intraoperative bleeding (median 125 vs. 300 mL, P = 0.003). No significant difference was observed in other postoperative short-term outcomes. Accuracy analysis indicated that the actual resected liver volume (ARLV) in the ARN-FI group was more accurate. CONCLUSIONS: ARN-FI was associated with less intraoperative bleeding and more accurate resection volume. These techniques may address existing challenges and provide rational guidance for laparoscopic anatomical S8 resection.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Ann Surg Oncol Assunto da revista: NEOPLASIAS Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Ann Surg Oncol Assunto da revista: NEOPLASIAS Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China