Your browser doesn't support javascript.
loading
Free-Breathing Compressed Sensing Cine Cardiac MRI for Assessment of Left Ventricular Strain by Feature Tracking in Children.
Xu, Ke; Xu, Rong; Xu, Hua-Yan; Xie, Lin-Jun; Yang, Zhi-Gang; Fu, Hang; Bai, Wei; Zhang, Lu; Zhou, Xiao-Yue; Guo, Ying-Kun.
Afiliação
  • Xu K; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Xu R; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Xu HY; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Xie LJ; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Yang ZG; Department of Radiology, West China Hospital, Sichuan University, Chengdu, China.
  • Fu H; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Bai W; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Zhang L; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
  • Zhou XY; Siemens Healthineers Digital Technology (Shanghai) Co., Ltd., Shanghai, China.
  • Guo YK; Department of Radiology, Key Laboratory of Obstetric and Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China.
J Magn Reson Imaging ; 59(5): 1832-1840, 2024 May.
Article em En | MEDLINE | ID: mdl-37681476
ABSTRACT

BACKGROUND:

Cardiac MRI feature-tracking (FT) with breath-holding (BH) cine balanced steady state free precession (bSSFP) imaging is well established. It is unclear whether FT-strain measurements can be reliably derived from free-breathing (FB) compressed sensing (CS) bSSFP imaging.

PURPOSE:

To compare left ventricular (LV) strain analysis and image quality of an FB CS bSSFP cine sequence with that of a conventional BH bSSFP sequence in children. STUDY TYPE Prospective.

SUBJECTS:

40 children able to perform BHs (cohort 1 [12.1 ± 2.2 years]) and 17 children unable to perform BHs (cohort 2 [5.2 ± 1.8 years]). FIELD STRENGTH/SEQUENCE 3T, bSSFP sequence with and without CS. ASSESSMENT Acquisition times and image quality were assessed. LV myocardial deformation parameters were compared between BH cine and FB CS cine studies in cohort 1. Strain indices and image quality of FB CS cine studies were also assessed in cohort 2. Intraobserver and interobserver variability of strain parameters was determined. STATISTICAL TESTS Paired t-test, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman analysis. A P-value <0.05 was considered statistically significant.

RESULTS:

In cohort 1, the mean acquisition time of the FB CS cine study was significantly lower than for conventional BH cine study (15.6 s vs. 209.4 s). No significant difference were found in global circumferential strain rate (P = 0.089), global longitudinal strain rate (P = 0.366) and EuroCMR image quality scores (P = 0.128) between BH and FB sequences in cohort 1. The overall image quality score of FB CS cine in cohort 2 was 3.5 ± 0.5 with acquisition time of 14.7 ± 2.1 s. Interobserver and intraobserver variabilities were good to excellent (ICC = 0.810 to 0.943). DATA

CONCLUSION:

FB CS cine imaging may be a promising alternative technique for strain assessment in pediatric patients with poor BH ability. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY Stage 1.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Função Ventricular Esquerda / Coração Limite: Child / Humans Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Função Ventricular Esquerda / Coração Limite: Child / Humans Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China