Comparative dosimetric study of spot-scanning proton therapy versus volumetric-modulated radiation therapy for extrahepatic bile duct cancer.
Ogata, Toshiyuki; Aibe, Norihiro; Kimoto, Takuya; Takenaka, Tadashi; Suzuki, Gen; Yamada, Kei; Yamazaki, Hideya.
Afiliação
  • Ogata T; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan. Electronic address: ogata@koto.kpu-m.ac.jp.
  • Aibe N; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan.
  • Kimoto T; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan.
  • Takenaka T; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan.
  • Suzuki G; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan.
  • Yamada K; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan.
  • Yamazaki H; Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566 Japan.
Med Dosim ; 49(1): 46-49, 2024.
Article em En | MEDLINE | ID: mdl-37925300
ABSTRACT
This study aimed to compare the dose distributions and clarify the dosimetric characteristics of spot-scanning proton therapy (SSPT) and photon volumetric modulated arc therapy (VMAT) for extrahepatic bile duct cancer (EBDC). This retrospective study included 10 patients with EBDC treated with real-time image-gated SSPT. Using the simultaneous integrated boost technique, the 2 prescription dose levels for planning target volumes were 72.6 and 44 Gy, delivered in 22 fractions. Plan quality comparisons were conducted by analyzing various parameters, including homogeneity, conformity, dose to organs at risk, and normal tissue complication probability (NTCP) for radiation-induced liver damage (RILD). The target dose distributions using SSPT were almost equivalent to those achieved using photon VMAT. There was a significant reduction in all liver dose parameters, the NTCP value for RILD, and kidney dose (mean, V12 Gy, and V18 Gy) in SSPT than in photon VMAT. No significant differences were observed in the intestinal doses in the high-dose area. Thus, compared with photon VMAT, SSPT for EBDC significantly reduced radiation doses to the liver and kidneys and has shown potential clinical benefits of reduced radiation-induced toxicity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lesões por Radiação / Ductos Biliares Extra-Hepáticos / Radioterapia de Intensidade Modulada / Terapia com Prótons / Neoplasias Limite: Humans Idioma: En Revista: Med Dosim Assunto da revista: RADIOTERAPIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lesões por Radiação / Ductos Biliares Extra-Hepáticos / Radioterapia de Intensidade Modulada / Terapia com Prótons / Neoplasias Limite: Humans Idioma: En Revista: Med Dosim Assunto da revista: RADIOTERAPIA Ano de publicação: 2024 Tipo de documento: Article