Your browser doesn't support javascript.
loading
Effect of Robotic-Assisted Gait at Different Levels of Guidance and Body Weight Support on Lower Limb Joint Kinematics and Coordination.
Cherni, Yosra; Blache, Yoann; Begon, Mickael; Ballaz, Laurent; Dal Maso, Fabien.
Afiliação
  • Cherni Y; Laboratoire de Simulation et Modélisation du Mouvement, École de Kinésiologie et des Sciences de l'Activité Physique, Université de Montréal, Montréal, QC H3T 1J4, Canada.
  • Blache Y; Centre de Recherche du CHU Ste Justine, Montréal, QC H3T 1C5, Canada.
  • Begon M; Centre de Recherche et d'Innovation Sur le Sport, Université de Lyon, 69007 Lyon, France.
  • Ballaz L; Laboratoire de Simulation et Modélisation du Mouvement, École de Kinésiologie et des Sciences de l'Activité Physique, Université de Montréal, Montréal, QC H3T 1J4, Canada.
  • Dal Maso F; Centre de Recherche du CHU Ste Justine, Montréal, QC H3T 1C5, Canada.
Sensors (Basel) ; 23(21)2023 Oct 29.
Article em En | MEDLINE | ID: mdl-37960500
ABSTRACT
The Lokomat provides task-oriented therapy for patients with gait disorders. This robotic technology drives the lower limbs in the sagittal plane. However, normative gait also involves motions in the coronal and transverse planes. This study aimed to compare the Lokomat with Treadmill gait through three-dimensional (3D)-joint kinematics and inter-joint coordination. Lower limb kinematics was recorded in 18 healthy participants who walked at 3 km/h on a Treadmill or in a Lokomat with nine combinations of Guidance (30%, 50%, 70%) and bodyweight support (30%, 50%, 70%). Compared to the Treadmill, the Lokomat altered pelvic rotation, decreased pelvis obliquity and hip adduction, and increased ankle rotation. Moreover, the Lokomat resulted in significantly slower velocity at the hip, knee, and ankle flexion compared to the treadmill condition. Moderate to strong correlations were observed between the Treadmill and Lokomat conditions in terms of inter-joint coordination between hip-knee (r = 0.67-0.91), hip-ankle (r = 0.66-0.85), and knee-ankle (r = 0.90-0.95). This study showed that some gait determinants, such as pelvis obliquity, rotation, and hip adduction, are altered when walking with Lokomat in comparison to a Treadmill. Kinematic deviations induced by the Lokomat were most prominent at high levels of bodyweight support. Interestingly, different levels of Guidance did not affect gait kinematics. The present results can help therapists to adequately select settings during Lokomat therapy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Robóticos Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Robóticos Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Canadá