Your browser doesn't support javascript.
loading
Efficiency of ultrafiltration/diafiltration in removing organic and elemental process equipment related leachables from biological therapeutics.
Sun, Bin; Hadidi, Mahsa; Santiago Nuñez, Jose; Song, Benben; Tumambac, Gilbert E; Wong, Ken; Kalinowski, Gregor; Hathcock, James J.
Afiliação
  • Sun B; Scientific Laboratory Services, Cytiva, Westborough, Massachusetts, USA.
  • Hadidi M; Purification Process Development Laboratory, Sanofi, Framingham, Massachusetts, USA.
  • Santiago Nuñez J; Scientific Laboratory Services, Cytiva, Westborough, Massachusetts, USA.
  • Song B; Scientific Laboratory Services, Cytiva, Westborough, Massachusetts, USA.
  • Tumambac GE; Regulatory and Validation Strategy, Cytiva, Westborough, Massachusetts, USA.
  • Wong K; Critical Material Management (Prior role was Extractables and Leachables SME), Sanofi, Swiftwater, Pennsylvania, USA.
  • Kalinowski G; Scientific Laboratory Services, Cytiva, Westborough, Massachusetts, USA.
  • Hathcock JJ; Regulatory and Validation Strategy, Cytiva, Westborough, Massachusetts, USA.
Biotechnol Prog ; 40(1): e3400, 2024.
Article em En | MEDLINE | ID: mdl-37964726
ABSTRACT
In the production of biological therapeutics such as monoclonal antibodies (mAbs), ultrafiltration and diafiltration (UF/DF) are widely regarded as effective downstream processing steps capable of removing process equipment related leachables (PERLs) introduced upstream of the UF/DF step. However, clearance data available in the literature are limited to species with low partition coefficients (log P) such as buffer ions, hydrophilic organic compounds, and some metal ions. Additional data for a wide range of PERLs including hydrophobic compounds and elemental impurities are needed to establish meaningful, comprehensive safety risk assessments. Herein, we report the results from studies investigating the clearance of seven different organic PERLs representing a wide range of characteristics (i.e., log P (-0.3 to 18)), and four model elements with different chemical properties spiked into a mAb formulation at 10 ppm and analyzed during clearance using gas chromatography-mass spectrometry (GC-MS), liquid chromatography-photodiode-array-mass spectrometry (LC-PDA-MS), and inductively coupled plasma mass spectrometry (ICP-MS). The clearance data showed ideal clearance and sieving of spiked organic PERLs with log P < 4, partial clearance of PERLs with 4 < log P < 9, and poor clearance of highly hydrophobic PERLs (log P > 9) after nine diafiltration volumes (DVs). Supplemental clearance studies on seven additional PERLs present at much lower concentration levels (0.1-1.5 ppm) in the mAb formulation upstream of UF/DF and three PERLs associated with the tangential flow filtration (TFF) equipment also demonstrated the similar correlations between log P and % clearance. For model elements, the findings suggest that UF/DF in general provides ideal clearance for elements. Evidence showed that the UF/DF process does not only help mitigate leachables risk from PERLs introduced upstream of UF/DF, but also from the TFF operation itself as all three TFF-related PERLs were effectively cleared. Overall, the UF/DF clearance presented in this work demonstrated whereas highly hydrophobic PERLs and elements that exist as charged species, particularly transition metal ions, may not be as effectively cleared and thus warrant further risk assessment; hydrophilic and some hydrophobic PERLs (log P < 4) are indeed well-cleared and thus present a lower overall safety risk.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrafiltração / Filtração Idioma: En Revista: Biotechnol Prog Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrafiltração / Filtração Idioma: En Revista: Biotechnol Prog Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos