Visual and refractive outcomes after implantation of two models of trifocal intraocular lenses in eyes with previous corneal ablation to treat hyperopia.
Mayordomo-Cerdá, Fernando; Ortega-Usobiaga, Julio; Baviera-Sabater, Julio; Bilbao-Calabuig, Rafael; Llovet-Osuna, Fernando; Druchkiv, Vasyl; Cobo-Soriano, Rosario.
Afiliação
  • Mayordomo-Cerdá F; Clinica Baviera-AIER Eye Group, GV Marqués del Turia 9, 46005, Valencia, Spain. fmayordomo@clinicabaviera.com.
  • Ortega-Usobiaga J; Clinica Baviera-AIER Eye Group, Calle La Merced 12, 4, 10, 46300, Utiel, Valencia, Spain. fmayordomo@clinicabaviera.com.
  • Baviera-Sabater J; Clinica Baviera-AIER Eye Group, Leizaola Lehendakariaen Kalea, 48011, Bilbao, Spain.
  • Bilbao-Calabuig R; Clinica Baviera-AIER Eye Group, GV Marqués del Turia 9, 46005, Valencia, Spain.
  • Llovet-Osuna F; Clinica Baviera-AIER Eye Group, Pº Castellana 20, 28046, Madrid, Spain.
  • Druchkiv V; Clinica Baviera-AIER Eye Group, Pº Castellana 20, 28046, Madrid, Spain.
  • Cobo-Soriano R; Clinica Baviera-AIER Eye Group, GV Marqués del Turia 9, 46005, Valencia, Spain.
Eye Vis (Lond) ; 10(1): 48, 2023 Dec 07.
Article em En | MEDLINE | ID: mdl-38057874
ABSTRACT

BACKGROUND:

To assess whether a trifocal intraocular lens (IOL) with neutral spherical aberration (SA) provides better visual and refractive outcomes than a trifocal IOL with negative SA after hyperopic corneal laser ablation.

METHODS:

This is a retrospective comparative study. Patients were classified according to the IOL implanted after cataract or clear lens phacoemulsification [group 1, PhysIOL FineVision Pod-F (negative SA); group 2, Rayner RayOne Trifocal (neutral SA)]. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction.

RESULTS:

198 eyes of 119 patients met the inclusion criteria. Group 1 comprised 120 eyes and group 2 comprised 78 eyes. At completion, the refractive and predictability results were significantly better in group 1 than in group 2 for manifest refraction spherical equivalent (MRSE) (P < 0.001). Differences were not significant for UDVA (P = 0.647), CDVA (P = 0.343), UIVA (P = 0.059), UNVA (P = 0.382), binocular UIVA (P = 0.157), or binocular UNVA (P = 0.527). Safety and efficacy indices in refractive lens exchange (RLE) eyes were 0.96 and 0.91, and 0.89 and 0.93 in groups 1 and 2, respectively (P = 0.254 and 0.168). Patient satisfaction was similar in both groups (P > 0.05, all items).

CONCLUSION:

In eyes previously treated with hyperopic corneal ablation, implantation of a trifocal IOL with neutral SA provided better efficacy and safety outcomes but worse predictability outcomes than those obtained with a trifocal model with negative SA.