Your browser doesn't support javascript.
loading
Optimization of the IntraVascular Oxygenator Catheter Using Angular Oscillation.
Farling, Stewart; Klitzman, Bruce; Vesel, Travis P; Cheifetz, Ira M; Straube, Tobias L; Deshusses, Marc A.
Afiliação
  • Farling S; Department of Civil & Environmental Engineering, Duke University, Durham, NC, USA.
  • Klitzman B; Kenan Plastic Surgery Research Labs, Duke University School of Medicine, Durham, NC, USA.
  • Vesel TP; Department of Biomedical Engineering, Duke University, Durham, NC, USA.
  • Cheifetz IM; Department of Pediatrics, Duke University School of Medicine, Durham, NC, USA.
  • Straube TL; Department of Pediatrics, Rainbow Babies and Children's Hospital, Case Western Reserve University, School of Medicine, Cleveland, OH, USA.
  • Deshusses MA; Department of Pediatrics, Duke University School of Medicine, Durham, NC, USA.
Ann Biomed Eng ; 52(3): 638-646, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38062312
ABSTRACT
We demonstrate a methodology which both improves oxygen transport and reduces or eliminates bubble formation in a novel hyperbaric membrane oxygenator catheter model system. Angular oscillations were introduced to a bundle of hollow fiber membranes (HFMs) supplied with hyperbaric 100% oxygen at average gauge pressures up to 0.35 barg. Oscillating bundles enabled delivery of an oxygen flux of up to 400 mL min-1 m-2 in an aqueous solution, a doubling over a previous non-oscillating setup. Similarly, the addition of angular oscillations facilitated a five-fold reduction in pressure to achieve similar oxygen flux. The increased angular speed of oscillation improved flux, while the addition of angular micro-oscillation variations resulted in flux reductions of 7-20% compared to continuous macro-oscillation only, depending on mixing conditions. However, semi-quantitative visual observation demonstrated that angular oscillations reduced or eliminated the instance of oxygen bubble formation on the HFMs. The modeled mass transfer coefficients indicated a quasi linear relationship between rotational velocity and flux, suggesting that faster oscillation speeds could further improve oxygen mass transport allowing for HFM bundles to maintain high oxygen fluxes while eliminating bubble formation. This encourages further development of our compact oxygenating catheter that could be used intravascularly.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Oxigenadores Idioma: En Revista: Ann Biomed Eng Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Oxigenadores Idioma: En Revista: Ann Biomed Eng Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos