Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis.
Lahuna, Loris; Greffier, Joël; Goupil, Jean; Frandon, Julien; Pastor, Maxime; De Oliveira, Fabien; Beregi, Jean Paul; Dabli, Djamel.
Afiliação
  • Lahuna L; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • Greffier J; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • Goupil J; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • Frandon J; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • Pastor M; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • De Oliveira F; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • Beregi JP; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
  • Dabli D; Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, CEDEX 9, 30029 Nîmes, France.
Diagnostics (Basel) ; 13(23)2023 Nov 21.
Article em En | MEDLINE | ID: mdl-38066732
ABSTRACT
Images from 64 patients undergoing an enhanced abdominal-pelvis scan at portal phase in dual-energy CT mode for the diagnosis of colitis or bowel obstruction were retrospectively analyzed. Acquisitions were performed on a third-generation dual-source CT (DSCT) 100/Sn150 kVp. Mixed images were generated, as well as virtual monoenergetic images (VMIs) at 40/50/60/70 keV. Objective image quality was assessed on VMIs and mixed images by measuring contrast, noise and contrast-to-noise ratio (CNR). Noise, smoothing and overall image quality were subjectively analyzed by two radiologists using Likert scales. For both patient groups, the noise decreased significantly according to the energy level from 40 to 60 keV by -47.2 ± 24.0% for bowel obstruction and -50.4 ± 18.2% for colitis. It was similar between 60 and 70 keV (p = 0.475 and 0.059, respectively). Noise values were significantly higher in VMIs than in mixed images, except for 70 keV (p = 0.53 and 0.071, respectively). Similar results were observed for contrast values, with a decrease between 40 and 70 keV of -56.3 ± 7.9% for bowel obstruction -56.2 ± 10.9% for colitis. The maximum CNR value was found at 60 keV compared to other energy levels and mixed images, but there was no significant difference with the other energy levels apart from 70 keV (-9.7 ± 9.8%) for bowel obstruction and 40 keV (-6.6 ± 8.2%) and 70 keV (-5.8 ± 9.2%) for colitis. The VMIs at 60 keV presented higher scores for all criteria for bowel obstruction and colitis, with no significant difference in smoothing score compared to mixed images (p = 0.119 and p = 0.888, respectively).