Your browser doesn't support javascript.
loading
Two-dimensional liquid chromatography measurement of meropenem concentration in synovial fluid of patients with periprosthetic joint infection.
Jia-Wei, He; Jing, Wang; Li, Cao; Xiao-Gang, Zhang; Guo-Qing, Li; Bo-Yong, Xu; Bao-Chao, Ji; Jun-Jie, Huang; Jun, Zhao.
Afiliação
  • Jia-Wei H; Department of Pharmacy, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Jing W; Department of Pharmacy, The Eighth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Li C; Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Xiao-Gang Z; Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Guo-Qing L; Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Bo-Yong X; Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Bao-Chao J; Department of Orthopaedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Jun-Jie H; College of Pharmacy, Xinjiang Medical University, Urumqi, Xinjiang, China.
  • Jun Z; Department of Pharmacy, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China.
Biomed Chromatogr ; 38(2): e5778, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38073142
Periprosthetic joint infection (PJI) is a catastrophic complication following joint replacement surgery. One potential treatment approach for PJI could be the combination of one-stage revision and intra-articular infusion of antibiotics. Meropenem is one of the commonly used intra-articular antibiotics in our institution. Determining the concentration of meropenem in the joint cavity could be crucial for optimizing its local application, effectively eradicating biofilm infection, and improving PJI treatment outcomes. In this study, we developed a simple, precise, and accurate method of two-dimensional liquid chromatography (2D-LC) for determining the concentration of meropenem in human synovial fluid. The method was then validated based on the guidelines of the Food and Drug Administration and the Chinese Pharmacopoeia. Meropenem showed good linearity in the range of 0.31-25.01 µg/mL (r ≥ .999). Selectivity, intra-day and inter-day precision and accuracy, extraction recovery, and stability validation results were all within the acceptance range. This method has been successfully applied to the determination of synovial fluid samples from PJI patients, providing a useful detection method for meropenem therapeutic drug monitoring (TDM) in PJI patients.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecções Relacionadas à Prótese / Artroplastia de Quadril / Artroplastia do Joelho Limite: Humans Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecções Relacionadas à Prótese / Artroplastia de Quadril / Artroplastia do Joelho Limite: Humans Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China