Your browser doesn't support javascript.
loading
The use of quantitative pupillometry in brain death determination: preliminary findings.
Lenga, Pavlina; Kühlwein, Daniel; Schönenberger, Silvia; Neumann, Jan-Oliver; Unterberg, Andreas W; Beynon, Christopher.
Afiliação
  • Lenga P; Department of Neurosurgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. pavlina.lenga@med.uni-heidelberg.de.
  • Kühlwein D; Department of Neurosurgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
  • Schönenberger S; Department of Neurology, Heidelberg University Hospital, Heidelberg, Germany.
  • Neumann JO; Department of Neurosurgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
  • Unterberg AW; Department of Neurosurgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
  • Beynon C; Department of Neurosurgery, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
Neurol Sci ; 45(5): 2165-2170, 2024 May.
Article em En | MEDLINE | ID: mdl-38082049
PURPOSE: Quantitative pupillometry (QP) has been increasingly applied in neurocritical care as an easy-to-use and reliable technique for evaluating the pupillary light reflex (PLR). Here, we report our preliminary findings on using QP for clinical brain death (BD) determination. MATERIALS: This retrospective study included 17 patients ≥ 18 years (mean age, 57.3 years; standard deviation, 15.8 years) with confirmed BD, as defined by German Guidelines for the determination of BD. The PLR was tested using the NPi®-200 Pupillometer (Neuroptics, Laguna Hill, USA), a handheld infrared device automatically tracking and analyzing pupil dynamics over 3 s. In addition, pupil diameter and neurological pupil index (NPi) were also evaluated. RESULTS: Intracerebral bleeding, subarachnoid hemorrhage, and hypoxic encephalopathy were the most prevalent causes of BD. In all patients, the NPi was 0 for both eyes, indicating the cessation of mid-brain function. The mean diameter was 4.9 mm (± 1.3) for the right pupil and 5.2 mm (±1.2) for the left pupil. CONCLUSIONS: QP is a valuable tool for the BD certification process to assess the loss of PLR due to the cessation of brain stem function. Furthermore, implementing QP before the withdrawal of life-sustaining therapy in brain-injured patients may reduce the rate of missed organ donation opportunities. Further studies are warranted to substantiate the feasibility and potential of this technique in treating patients and identify suitable candidates for this technique during the BD certification process.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reflexo Pupilar / Morte Encefálica Limite: Humans / Middle aged Idioma: En Revista: Neurol Sci Assunto da revista: NEUROLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reflexo Pupilar / Morte Encefálica Limite: Humans / Middle aged Idioma: En Revista: Neurol Sci Assunto da revista: NEUROLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha