Your browser doesn't support javascript.
loading
Design of a dual Ir-Eu tag for fluorescent visualization and ICP-MS quantification of SIRPα and its host cells.
Liu, Chunlan; Li, Pengtao; Yan, Xiaowen; Yang, Limin; Liu, Pingguo; Wang, Qiuquan.
Afiliação
  • Liu C; Department of Chemistry & the MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China.
  • Li P; College of Chemistry and Bioengineering, Yichun University, Yichun, 336000, China.
  • Yan X; Department of Hepatobiliary Surgery & Fujian Provincial Key Laboratory of Chronic Liver Disease and Hepatocellular Carcinoma, Xiamen Key Laboratory of Translational Medical of Digestive System Tumor, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361000,
  • Yang L; Department of Chemistry & the MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China.
  • Liu P; Department of Chemistry & the MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China.
  • Wang Q; Department of Hepatobiliary Surgery & Fujian Provincial Key Laboratory of Chronic Liver Disease and Hepatocellular Carcinoma, Xiamen Key Laboratory of Translational Medical of Digestive System Tumor, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361000,
Anal Bioanal Chem ; 416(11): 2691-2697, 2024 May.
Article em En | MEDLINE | ID: mdl-38133669
ABSTRACT
With the expansion of ICP-MS application into the field of bioanalysis, there is an urgent need for novel element tags today. Here, we report the design of a dual-element Ir-Eu tag, opening the door to simultaneous fluorescent imaging and ICP-MS quantification. The ratio of 153Eu/193Ir may serve as a precision control of the labeling process, allowing internal validation of the quantitative results obtained. As for SIRPα and its host cell analysis exemplified here, the Ir-Eu tag demonstrated superior figures of ICP-MS quantification with the LOD (3σ) down to 0.5 (153Eu) and 1.1 (193Ir) pM SIRPα and 220 (153Eu) and 830 (193Ir) RAW264.7 cells more than 130 times more sensitive compared with the LOD (3σ) of 65.2 pM SIRPα at 612 nm using fluorometry. Not limited to these demonstrations, we believe that the design ideas of the dual Ir-Eu tags should be applicable to various cases of bioanalysis when dual optical profiling and ICP-MS quantification are indispensable.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas Limite: Animals Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China