Your browser doesn't support javascript.
loading
Simultaneous detection of norepinephrine and 5-hydroxytryptophan using poly-alizarin/multi-walled carbon nanotubes-graphene modified carbon fiber microelectrode array sensor.
Zeng, Chaoying; Li, Yulan; Zhu, Mingfang; Du, Zengcheng; Liang, Huanru; Chen, Qiqing; Ye, Hongqing; Li, Rui; Liu, Wenhao.
Afiliação
  • Zeng C; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China. Electronic address: 843017341@qq.com.
  • Li Y; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
  • Zhu M; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China. Electronic address: zhumfgy@126.com.
  • Du Z; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
  • Liang H; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
  • Chen Q; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
  • Ye H; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
  • Li R; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
  • Liu W; College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou, 510006, PR China.
Talanta ; 270: 125565, 2024 Apr 01.
Article em En | MEDLINE | ID: mdl-38154355
ABSTRACT
Multi-walled carbon nanotubes, graphene and alizarin polymer composites coated carbon fiber microelectrode array sensor (p-AZ/MWCNT-GR/CFMEA) was constructed and used for the simultaneous detection of norepinephrine (NE) and 5-hydroxytryptophan (5-HT). The morphology and structural characteristics of sensor are characterized using scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. Its electrochemical behavior has been studied with cyclic voltammetry and electrochemical impedance spectroscopy. The sensor exhibits excellent electrochemical activity for the oxidation of NE and 5-HT, two well separated oxidation peaks with the peak potential difference of 220 mV are observed on the cyclic voltammogram. NE and 5-HT both show two electrons and two protons electrochemical reaction on the p-AZ/MWCNT-GR/CFMEA. Under the optimized experiment conditions, the linear ranges of the sensor for NE and 5-HT are 0. 08- 8 µM and 0. 1-20 µM with detection limits of 4. 22 nM and 14. 2 nM (S/N = 3), respectively. In addition, the microsensor array show good reproducibility, stability and selectivity for the determination of NE and 5-HT. Finally, the p-AZ/MWCNT-GR/CFMEA is applied to the simultaneous detection of NE and 5-HT in human serum samples and macrophages.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article