Validation and Calibration for Embedding Rating of Perceived Exertion Into High-Intensity Interval Exercise in Adolescents: A Lab-Based Study.
Liu, Yong; Williams, Craig A; Weston, Kathryn L; Duncombe, Stephanie L; Malik, Adam A; Barker, Alan R.
Afiliação
  • Liu Y; Children's Health and Exercise Research Centre, Public Health and Sports Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter,United Kingdom.
  • Williams CA; Children's Health and Exercise Research Centre, Public Health and Sports Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter,United Kingdom.
  • Weston KL; Children's Health and Exercise Research Centre, Public Health and Sports Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter,United Kingdom.
  • Duncombe SL; Department of Psychological Sciences and Health, University of Strathclyde, Glasgow,United Kingdom.
  • Malik AA; Children's Health and Exercise Research Centre, Public Health and Sports Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter,United Kingdom.
  • Barker AR; School of Human Movement and Nutrition Sciences, The University of Queensland, Saint Lucia, QLD,Australia.
Pediatr Exerc Sci ; : 1-7, 2024 Jan 08.
Article em En | MEDLINE | ID: mdl-38194950
ABSTRACT

PURPOSE:

Rating of perceived exertion (RPE) is a convenient and cost-effective tool that can be used to monitor high-intensity interval exercise (HIIE). However, no methodological study has demonstrated the validity of RPE in this context. Therefore, the aim of this study was to validate and calibrate RPE for monitoring HIIE in adolescents.

METHODS:

RPE, heart rate (HR), and oxygen uptake (V˙O2) data were retrospectively extracted from 3 lab-based crossover studies, with a pooled sample size of 45 adolescents, performing either cycling-based or running-based HIIE sessions. Within-participant correlations were calculated for RPE-HR and RPE-V˙O2, and receiver operator characteristic curve analysis was used to establish RPE cut points.

RESULTS:

The results showed that RPE-HR demonstrated acceptable criterion validity (r = .53-.74, P < .01), while RPE-V˙O2 had poor validity (r = .40-.48, P < .01), except for HIIE at 100% peak power (r = .59, P < .01). RPE cut points of 4 and 5 were established in corresponding to HR/V˙O2 based thresholds.

CONCLUSION:

RPE has some utility in evaluating intensity during lab-based running or cycling HIIE in adolescents. Future studies should expand the validation and calibration of RPE for prescribing and monitoring HIIE in children and adolescents in field-based contexts.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Pediatr Exerc Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Pediatr Exerc Sci Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido