Your browser doesn't support javascript.
loading
A benzoxazole-triphenylamine conjugated fluorogenic probe for specific detection of sarin gas mimic diethylchlorophosphate.
Sultana, Tuhina; Mahato, Manas; Tohora, Najmin; Ahamed, Sabbir; Maiti, Arpita; Ghanta, Susanta; Das, Sudhir Kumar.
Afiliação
  • Sultana T; Department of Chemistry, University of North Bengal, Raja Rammohunpur, Darjeeling, West Bengal 734013, India. sudhirkumardas@nbu.ac.in.
  • Mahato M; Department of Chemistry, University of North Bengal, Raja Rammohunpur, Darjeeling, West Bengal 734013, India. sudhirkumardas@nbu.ac.in.
  • Tohora N; Department of Chemistry, University of North Bengal, Raja Rammohunpur, Darjeeling, West Bengal 734013, India. sudhirkumardas@nbu.ac.in.
  • Ahamed S; Department of Chemistry, University of North Bengal, Raja Rammohunpur, Darjeeling, West Bengal 734013, India. sudhirkumardas@nbu.ac.in.
  • Maiti A; Department of Chemistry, University of North Bengal, Raja Rammohunpur, Darjeeling, West Bengal 734013, India. sudhirkumardas@nbu.ac.in.
  • Ghanta S; Department of Chemistry, National Institute of Technology, Barjala, Jirania, Agartala, Tripura 799046, India.
  • Das SK; Department of Chemistry, University of North Bengal, Raja Rammohunpur, Darjeeling, West Bengal 734013, India. sudhirkumardas@nbu.ac.in.
Anal Methods ; 16(5): 759-771, 2024 Feb 01.
Article em En | MEDLINE | ID: mdl-38227020
ABSTRACT
In this study, an excellent chromo-fluorogenic PMPA probe, (E)-4-(((4-(benzoxazole-2-yl)phenyl)imino)methyl)-N,N-diphenylamine, is introduced for the detection of sarin gas mimic diethyl chlorophosphate (DCP) in solution and gaseous phases. On adding DCP into PMPA solution in a pure DMSO and water-DMSO (4 1) medium, it exhibits a hypsochromic shift from yellow to colorless and from no fluorescence to highly intense blue-violet photoluminescence via the formation of a phosphorylated PMPA-DCP product due to the inhibition of intramolecular charge transfer (ICT) and photoinduced electron transfer (PET) mechanism. The sensor could detect DCP in the presence of several other notorious guest analytes with a detection limit in the µM range. Moreover, to accomplish the on-spot detection of DCP and explore the practical applicability of the probe, a paper strip-based test kit, "dip-stick" method, and, more interestingly, a real sample analysis was demonstrated in spiked soil samples.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia