Your browser doesn't support javascript.
loading
3D printing assisted MIPO for treatment of complex middle-proximal humeral shaft fractures.
Hu, Chaoran; Qiu, Bing; Cen, Chaode; Luo, Qin; Cao, Yongfei.
Afiliação
  • Hu C; Department of Orthopedics, The Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, 550014, Guizhou, China.
  • Qiu B; Department of Orthopedics, The Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, 550014, Guizhou, China.
  • Cen C; Department of Orthopedics, The Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, 550014, Guizhou, China.
  • Luo Q; Department of Orthopedics, The Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, 550014, Guizhou, China.
  • Cao Y; Department of Orthopedics, The Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, 550014, Guizhou, China. ayouvs@vip.qq.com.
BMC Musculoskelet Disord ; 25(1): 93, 2024 Jan 24.
Article em En | MEDLINE | ID: mdl-38267894
ABSTRACT

BACKGROUND:

This study was designed to explore the clinical efficacy of 3-dimensional (3D) printing assisted minimally invasive percutaneous plate osteosynthesis (MIPO) technique by comparing the clinical outcomes with traditional open reduction and internal plating fixation (ORIF) for treating complex middle-proximal humerus fractures (AO 12C fracture type). MATERIALS AND

METHODS:

The data of 42 participants who received a complicated middle-proximal humerus fracture from the beginning of 2018 to the end of 2022 were retrospectively analyzed. All patients were assigned to two groups MIPO with detailed preoperative planning assisted by 3D printing technique (MIPO group), and traditional ORIF (ORIF group).

RESULTS:

This study included 21 patients in the ORIF group and 21 patients in the MIPO group. All patients were followed-up for at least one year (mean 16.12 ± 4.13 months), and no difference was observed in the range of shoulder joint motion (ROM), Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) scores and Constant scores between the two groups. However, the occurrence of complications (surgical incision site infection, implant loosening, bone nonunion and radial nerve palsy) in ORIF group was remarkably higher compared to the MIPO group. All the cases achieved bone union within the MIPO group. Significant differences were found in surgical time, intraoperative blood loss and fracture healing time between the two groups.

CONCLUSION:

Preoperative 3D printing assisted MIPO technique exhibits obvious advantages in high operational efficiency and low occurrence of complications, which is worthy of clinical application for treating complex middle-proximal humeral shaft fractures.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas do Ombro / Perda Sanguínea Cirúrgica Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: BMC Musculoskelet Disord Assunto da revista: FISIOLOGIA / ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fraturas do Ombro / Perda Sanguínea Cirúrgica Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: BMC Musculoskelet Disord Assunto da revista: FISIOLOGIA / ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China