Your browser doesn't support javascript.
loading
A comparison of minimum segment models for the estimation of centre of mass position and velocity for slip recovery during a bathtub transfer task.
Collins, Mackenzie; Levine, Iris C; Gosine, Philippa C; Montgomery, Roger E; Nirmalanathan, Konika; Novak, Alison C.
Afiliação
  • Collins M; KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, 13-000, 550 University Avenue, Toronto, Ontario M5G 2A2, Canada.
  • Levine IC; KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, 13-000, 550 University Avenue, Toronto, Ontario M5G 2A2, Canada.
  • Gosine PC; KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, 13-000, 550 University Avenue, Toronto, Ontario M5G 2A2, Canada.
  • Montgomery RE; KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, 13-000, 550 University Avenue, Toronto, Ontario M5G 2A2, Canada.
  • Nirmalanathan K; KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, 13-000, 550 University Avenue, Toronto, Ontario M5G 2A2, Canada.
  • Novak AC; KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, 13-000, 550 University Avenue, Toronto, Ontario M5G 2A2, Canada; Rehabilitation Sciences Institute, University of Toronto, 500 University Avenue, Toronto, Ontario M5G 1V7, Canada; Faculty of Kinesiology and Physic
Gait Posture ; 109: 153-157, 2024 03.
Article em En | MEDLINE | ID: mdl-38309126
ABSTRACT

BACKGROUND:

Exploring the use of minimum marker sets is important for balancing the technical quality of motion capture with challenging data collection environments and protocols. While minimum marker sets have been demonstrated to be appropriate for evaluation of some motion patterns, there is limited evidence to support model choices for abrupt, asymmetrical, non-cyclic motion such as balance disturbance during a bathtub exit task. RESEARCH QUESTION How effective are six models of reduced complexity for the estimation of centre of mass (COM) displacement and velocity, relative to a full-body model.

METHODS:

Eight participants completed a bathtub exit task. Participants received a balance perturbation as they crossed the bathtub rim, stepping from a soapy wet bathtub to a dry floor. Six reduced models were developed from the full, 72-marker, 12 segment 3D kinematic data set. Peak displacement and velocity of the body COM, and RMSE (relative to the full-body model) for displacement and velocity of the body COM were determined for each model.

RESULTS:

Main effects were observed for peak right, left, anterior, posterior, upwards and downwards motion, and peak left, anterior, posterior, upwards and downwards velocity. Time-varying (RMSE) was smaller for models including the thighs than models not containing the thighs. In contrast, inclusion of upper arm, forearm, and hand segments did not improve model performance. The model containing the sacrum marker only consistently performed the worst across peak and RMSE metrics.

SIGNIFICANCE:

Findings suggest a simplified centre of mass model may adequately capture abrupt, asymmetrical, non-cyclic tasks, such as balance disturbance recovery during obstacle crossing. A reduced kinematic model should include the thighs, trunk and pelvis segments, although models that are more complex are recommended, depending on the metrics of interest.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pelve / Braço Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Gait Posture Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pelve / Braço Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Gait Posture Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Canadá