Your browser doesn't support javascript.
loading
Detection of paroxysmal atrial fibrillation preceding persistent atrial fibrillation in a horse using an implantable loop recorder with remote monitoring.
Vernemmen, I; Van Steenkiste, G; Decloedt, A; Meert, H; Walser, U; van Loon, G.
Afiliação
  • Vernemmen I; Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium. Electronic address: Ingrid.Vernemmen@ugent.be.
  • Van Steenkiste G; Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
  • Decloedt A; Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
  • Meert H; Biotronik Belgium, Medialaan 36, 1800 Vilvoorde, Belgium.
  • Walser U; Biotronik Belgium, Medialaan 36, 1800 Vilvoorde, Belgium.
  • van Loon G; Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
J Vet Cardiol ; 52: 19-27, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38402667
ABSTRACT
Implantable loop recorders (ILRs) are increasingly used in equine cardiology to detect arrhythmias in the context of collapse, poor performance or monitoring for recurrence of atrial fibrillation (AF). However to date, the ILR has never been reported to be used with a remote monitoring functionality in horses, therefore the arrhythmia is only discovered when a clinician interrogates the ILR using dedicated equipment, which might delay diagnosis and intervention. This case report describes the use of an ILR with remote monitoring functionality in a horse with recurrent AF. The remote monitoring consisted of a transmission device located in the stable allowing daily transmission of arrhythmia recordings and functioning messages to an online server, available for the clinician to evaluate without specialised equipment. The ILR detected an episode of paroxysmal AF approximately three months after implantation. Seven months after implantation, initiation of persistent AF was seen on an episode misclassified by the ILR as bradycardia, and the horse was retired. This report shows the feasibility and benefits of remote monitoring for ILRs in horses, but also the shortcomings of current algorithms to interpret the equine electrocardiogram.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Eletrocardiografia Ambulatorial / Doenças dos Cavalos Limite: Animals Idioma: En Revista: J Vet Cardiol Assunto da revista: CARDIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Eletrocardiografia Ambulatorial / Doenças dos Cavalos Limite: Animals Idioma: En Revista: J Vet Cardiol Assunto da revista: CARDIOLOGIA / MEDICINA VETERINARIA Ano de publicação: 2024 Tipo de documento: Article