On-site infrasound calibration to correct wave parameter estimation.
Kristoffersen, S K; Le Pichon, A; Schwardt, M; Vincent, P; Doury, B; Larsonnier, F; Pilger, C.
Afiliação
  • Kristoffersen SK; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Le Pichon A; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Schwardt M; Bundesanstalt für Geowissenschaften und Rohstoffe, B4.3, Hanover, Germany.
  • Vincent P; Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany.
  • Doury B; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Larsonnier F; Comprehensive Nuclear-Test-Ban Treaty Organization, Vienna, Austria.
  • Pilger C; CEA, DAM, DIF, F-91297 Arpajon, France.
J Acoust Soc Am ; 155(3): 1780-1798, 2024 Mar 01.
Article em En | MEDLINE | ID: mdl-38445987
ABSTRACT
The International Monitoring System (IMS) has been established as part of the Comprehensive Nuclear-Test-Ban Treaty to monitor nuclear testing and is comprised of infrasound, hydroacoustic, seismic, and radionuclide stations; it is also used more widely by the scientific community for scientific and civilian applications. For the infrasound stations, on-site calibration provides an accurate measure of the sensor (microbarometer + wind-noise reduction system) frequency response, used to monitor that the sensor response remains within tolerance of the baseline established when the station is certified. However, this on-site calibration can also be used when there are issues/defects with the sensors. As a result, the on-site calibration can be used to correct wave parameter estimations and increase the detection capability of the station. Examples using an experimental sensor at the IMS station IS26 (Germany) and IS47 (South Africa) demonstrate that errors of several degrees and tens of m/s can be introduced, under certain conditions, for the back azimuth and trace velocity, respectively. By using the on-site calibration, these errors are removed, and the correct back azimuth, trace velocity and amplitude are retrieved. This can be especially useful for the identification of infrasound signals, and the localization of their sources.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França