Your browser doesn't support javascript.
loading
Ventricular Arrhythmias and Sudden Cardiac Death in Left Ventricular Assist Device Patients Without Implantable Cardioverter Defibrillators.
Gokhale, Sanket; Malesz, Alexandra; Masha, Luke.
Afiliação
  • Gokhale S; From the Division of Cardiology, Knight Cardiovascular Institute, Oregon Health Science University, Portland, Oregon.
  • Malesz A; Department of Internal Medicine, Oregon Health Science University, Portland, Oregon.
  • Masha L; From the Division of Cardiology, Knight Cardiovascular Institute, Oregon Health Science University, Portland, Oregon.
ASAIO J ; 70(9): 773-777, 2024 09 01.
Article em En | MEDLINE | ID: mdl-38457484
ABSTRACT
Patients with left ventricular assist devices (LVAD) can develop sustained ventricular arrhythmias (VA). The history and presentation of VA in implantable cardioverter defibrillator (ICD)-naive patients with LVAD is not well described in the literature and the risks/benefits of ICD implantation are unknown. This single-center retrospective cohort study included patients >18 years old who did not have an ICD during LVAD implantation from 2010 to 2022. The primary outcome was VA event rate per 100 patient-years. Two hundred thirty-seven patients underwent LVAD implantation and we identified 46 (19.4%) ICD naive patients. The etiology of heart failure in most patients was nonischemic cardiomyopathy (67.4%). Of all patients, only five were found to have documented VA. Only two episodes of VA occurred in the ambulatory setting. The estimated index VA rate was 5.89 events per 100 patient-years in our entire ICD-naive LVAD population. In the ambulatory ICD-naive population, the estimated VA rate was 2.42 events per 100 patient-years with no associated mortality. The rate of index VA in ICD-naive patients was below thresholds associated with benefits from ICD insertion. No ambulatory mortality from VA was seen and VA was well tolerated by the LVAD population. Perioperative VA in this population is associated with high mortality.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Coração Auxiliar / Morte Súbita Cardíaca / Desfibriladores Implantáveis Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: ASAIO J Assunto da revista: TRANSPLANTE Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Coração Auxiliar / Morte Súbita Cardíaca / Desfibriladores Implantáveis Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: ASAIO J Assunto da revista: TRANSPLANTE Ano de publicação: 2024 Tipo de documento: Article