Your browser doesn't support javascript.
loading
A Fast and Simple Solid Phase Extraction-Based Method for Glucosinolate Determination: An Alternative to the ISO-9167 Method.
Li, Yanfang; Zhang, Mengliang; Pehrsson, Pamela; Harnly, James M; Chen, Pei; Sun, Jianghao.
Afiliação
  • Li Y; Methods and Application of Food Composition Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD 20705, USA.
  • Zhang M; Department of Chemistry, Middle Tennessee State University, Murfreesboro, TN 37132, USA.
  • Pehrsson P; Department of Chemistry, Middle Tennessee State University, Murfreesboro, TN 37132, USA.
  • Harnly JM; Methods and Application of Food Composition Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD 20705, USA.
  • Chen P; Methods and Application of Food Composition Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD 20705, USA.
  • Sun J; Methods and Application of Food Composition Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD 20705, USA.
Foods ; 13(5)2024 Feb 21.
Article em En | MEDLINE | ID: mdl-38472763
ABSTRACT
Glucosinolates (GLSs) are a well-studied sulfur-containing compound found in Brassicaceae plants that play critical roles in plant resistance and human health. Correctly identifying and reliably quantifying the total and individual GLS content is of great importance. An improved method as an alternative to the ISO 9167-1 (ISO) method is developed in the present study. An efficient extraction and purification procedure is proposed with a commercially available dimethylaminopropyl (DEA)-based weak anion exchange solid-phase extraction (SPE) cartridge instead of using the self-prepared ion-exchange columns in the ISO method. The GLSs are identified and quantified by ultra high-performance liquid chromatography (UHPLC) high-resolution mass spectrometry (HRMS). The method demonstrates a comparable quantification of total and individual GLSs on certified rapeseeds and other Brassicaceae vegetables when compared to the ISO method. The developed SPE method is simpler and more efficient, thus allowing for applications to a large sample size with reduced analysis time, improved repeatability and accuracy, and possible automation.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Foods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Foods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos