Your browser doesn't support javascript.
loading
Improving hybrid image and structure-based deformable image registration for large internal deformations.
Lorenzo Polo, A; Nix, M; Thompson, C; O'Hara, C; Entwisle, J; Murray, L; Appelt, A; Weistrand, O; Svensson, S.
Afiliação
  • Lorenzo Polo A; RaySearch Laboratories, SE-104 30 Stockholm, Sweden.
  • Nix M; Leeds Cancer Centre, Department of Medical Physics, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
  • Thompson C; Leeds Cancer Centre, Department of Medical Physics, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
  • O'Hara C; Leeds Cancer Centre, Department of Medical Physics, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
  • Entwisle J; Leeds Cancer Centre, Department of Medical Physics, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
  • Murray L; Leeds Cancer Centre, Department of Clinical Oncology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
  • Appelt A; Leeds Institute of Medical Research at St James's, University of Leeds, Leeds, United Kingdom.
  • Weistrand O; Leeds Cancer Centre, Department of Medical Physics, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
  • Svensson S; Leeds Institute of Medical Research at St James's, University of Leeds, Leeds, United Kingdom.
Phys Med Biol ; 69(9)2024 Apr 17.
Article em En | MEDLINE | ID: mdl-38518382
ABSTRACT
Objective.Deformable image registration (DIR) is a widely used technique in radiotherapy. Complex deformations, resulting from large anatomical changes, are a regular challenge. DIR algorithms generally seek a balance between capturing large deformations and preserving a smooth deformation vector field (DVF). We propose a novel structure-based term that can enhance the registration efficacy while ensuring a smooth DVF.Approach.The proposed novel similarity metric for controlling structures was introduced as a new term into a commercially available algorithm. Its performance was compared to the original algorithm using a dataset of 46 patients who received pelvic re-irradiation, many of which exhibited complex deformations.Main results.The mean Dice Similarity Coefficient (DSC) under the improved algorithm was 0.96, 0.94, 0.76, and 0.91 for bladder, rectum, colon, and bone respectively, compared to 0.69, 0.89, 0.62, and 0.88 for the original algorithm. The improvement was more pronounced for complex deformations.Significance.With this work, we have demonstrated that the proposed term is able to improve registration accuracy for complex cases while maintaining realistic deformations.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Tomografia Computadorizada por Raios X Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Suécia