Your browser doesn't support javascript.
loading
Perfluorobutane (Sonazoid) Contrast-enhanced ultrasound to diagnose hepatocellular carcinoma: A systematic review and meta-analysis.
Chen, Yujia; Zhu, Wenjun; Yi, Yunyun; Cao, Huali; Chen, Fan; Zhu, Qinling.
Afiliação
  • Chen Y; Department of Ultrasound, Affiliated Hospital of Jiaxing University, First Hospital of Jiaxing, Jiaxing. cyjzjhn@163.com.
  • Zhu W; Department of Ultrasound, Affiliated Hospital of Jiaxing University, First Hospital of Jiaxing, Jiaxing.
  • Yi Y; Department of Ultrasound, Affiliated Hospital of Jiaxing University, First Hospital of Jiaxing, Jiaxing.
  • Cao H; Department of Ultrasound, Affiliated Hospital of Jiaxing University, First Hospital of Jiaxing, Jiaxing.
  • Chen F; Department of Ultrasound, Affiliated Hospital of Jiaxing University, First Hospital of Jiaxing, Jiaxing.
  • Zhu Q; Department of Ultrasound, Affiliated Hospital of Jiaxing University, First Hospital of Jiaxing, Jiaxing.
Med Ultrason ; 26(2): 187-196, 2024 Jun 21.
Article em En | MEDLINE | ID: mdl-38537180
ABSTRACT

AIM:

This meta-analysis aimed to assess the precision of Sonazoid contrast-enhanced ultrasound (CEUS) to distinguish hepatocellular carcinoma (HCC) from focal liver lesions (FLLs). MATERIAL AND

METHODS:

The Cochrane Library, Embase, PubMed, and Web of Science databases were systematically searched and checked for studies using Sonazoid CEUS to characterize HCC. A comprehensive meta-analysis was conducted, involving data pooling, subgroup analyses, meta-regression, and investigation of publication bias.

RESULTS:

The meta-analysis included fourteen studies. The overall diagnostic accuracy for characterizing HCC was as follows (all ranges show the 95% confidence interval) pooled sensitivity of 0.87 (0.80-0.92), pooled specificity of 0.95 (0.91-0.97), and a diagnostic odds ratio of 121 (61-241). The overall weighted area under the curve was 0.97 (0.95-0.98). The pooled sensitivity, specificity, and diagnostic odds ratio for Sonazoid and Sonovue were 0.75 (0.63- 0.84), 0.97 (0.86-0.99), 82 (15-445); and 0.64 (0.51-0.76), 0.98 (0.91-0.99), 72 (17-311), respectively. The sources of heterogeneity were identified as the study location, prevailing risk factor, reference diagnosis standard, criteria of Sonazoid CUES, and the proportion of cases of HCC. We observed no potential publication bias.

CONCLUSION:

Sonazoid CEUS is efficient to distinguish HCC from FLLs, with good sensitivity and specificity. It is comparable to Sonovue CEUS to diagnose HCC.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Óxidos / Ultrassonografia / Carcinoma Hepatocelular / Meios de Contraste / Ferro / Neoplasias Hepáticas Limite: Humans Idioma: En Revista: Med Ultrason Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Óxidos / Ultrassonografia / Carcinoma Hepatocelular / Meios de Contraste / Ferro / Neoplasias Hepáticas Limite: Humans Idioma: En Revista: Med Ultrason Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article