Your browser doesn't support javascript.
loading
Real-World Analysis of the Efficacy of Bimatoprost Sustained-Release Glaucoma Implant Where American Indians Comprise the Largest Minority Population.
Sarkisian, Steven R; Mitchell, Evann C.
Afiliação
  • Sarkisian SR; Research & Clinical Trials, Oklahoma Eye Surgeons, Oklahoma City, OK, USA.
  • Mitchell EC; College of Medicine, University of Oklahoma, Oklahoma City, OK, USA.
Clin Ophthalmol ; 18: 917-927, 2024.
Article em En | MEDLINE | ID: mdl-38550359
ABSTRACT

Purpose:

To assess the effectiveness and safety of bimatoprost sustained release (SR) glaucoma implant as a treatment for open-angle glaucoma and ocular hypertension in a real-world private practice setting with a significant American Indian population.

Methods:

This retrospective study included 156 eyes from adult patients who received a single injection of bimatoprost implant between June 2020 and May 2022 at the Oklahoma Eye Surgeons. Patients were stratified by baseline intraocular pressure (IOP) (≥21 mmHg versus IOP<21 mmHg). The co-primary endpoints were changes in the mean IOP and the number of topical IOP-lowering medications from baseline to Month 6.

Results:

At 6 months, eyes with baseline IOP≥21 mmHg had a significantly lower mean IOP (19.85±8.01 versus 26.25±4.84 mmHg; p<0.0001) and the mean number of IOP-lowering medications (1.04±1.44 versus 1.38±1.50; p=0.048) compared with baseline. One year after implantation, 73.58% of eyes had a ≥20% reduction in IOP, 41.51% were medication-free and 30.19% were receiving at least one fewer medication. Among eyes with baseline IOP<21 mmHg, there was a significant reduction in the mean number of IOP-lowering medicines by Month 6 (0.61±1.03 versus 1.93±1.21 at baseline; p<0.0001), with no change in IOP. At 12 months, 24.27% of eyes had a ≥20% decrease in IOP, 43.69% of eyes did not require any medications and 63.11% had at least one fewer medication compared with baseline. An analysis using Welch's two-sample t-test showed no significant differences in the outcomes between the overall population and the American Indian population (number of eyes, 23).

Conclusion:

Bimatoprost SR glaucoma implant lowered IOP in eyes with high, uncontrolled baseline IOP, while it reduced the number of medications in eyes with a controlled baseline IOP. No clinically meaningful and statistically significant differences in the efficacy of bimatoprost were observed in patients of American Indian descent.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Clin Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Clin Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos