Accuracy, Repeatability, and Reproducibility of a Hand-Held Structured-Light 3D Scanner across Multi-Site Settings in Lower Limb Prosthetics.
Cutti, Andrea Giovanni; Santi, Maria Grazia; Hansen, Andrew H; Fatone, Stefania.
Afiliação
  • Cutti AG; INAIL, Via Rabuina 14, Vigorso di Budrio, 40054 Bologna, Italy.
  • Santi MG; Department of Industrial Engineering, University of Padova, 35131 Padova, Italy.
  • Hansen AH; Minneapolis VA Health Care System, One Veterans Drive, Minneapolis, MN 55417, USA.
  • Fatone S; Department of Family Medicine and Community Health, Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455, USA.
Sensors (Basel) ; 24(7)2024 Apr 07.
Article em En | MEDLINE | ID: mdl-38610559
ABSTRACT
The aim of this work was to assess the accuracy, repeatability, and reproducibility of a hand-held, structured-light 3D scanner (EINScan Pro 2X Plus with High Definition Prime Pack, SHINING 3D Tech. Co., Ltd., Hangzhou, China), to support its potential use in multi-site settings on lower limb prosthetics. Four limb models with different shapes were fabricated and scanned with a metrological 3D scanner (EINScan Laser FreeScan 5X, SHINING 3D Tech. Co., Ltd., Hangzhou, China) by a professional operator (OP0). Limb models were then mailed to three sites where two operators (OP1, OP2) scanned them using their own structured-light 3D scanner (same model). OP1 scanned limb models twice (OP1-A, OP1-B). OP0, OP1-A, and OP2 scans were compared for accuracy, OP1-A and OP1-B for repeatability, and OP1-A and OP2 for reproducibility. Among all comparisons, the mean radial error was <0.25 mm, mean angular error was <4°, and root mean square error of the radial distance was <1 mm. Moreover, limits of agreement were <3.5% for perimeters and volumes. By comparing these results with respect to clinically-relevant thresholds and to the literature available on other 3D scanners, we conclude that the EINScan Pro 2X Plus 3D Scanner with High Definition Prime Pack has good accuracy, repeatability, and reproducibility, supporting its use in multi-site settings.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Extremidade Superior / Mãos Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Extremidade Superior / Mãos Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália