Ex vivo kidney machine perfusion: meta-analysis of randomized clinical trials.
Kang, Minseok; Kim, Seonju; Choi, Ji Yoon; Kim, Kyeong Sik; Jung, Yun Kyung; Park, Boyoung; Choi, Dongho.
Afiliação
  • Kang M; Department of Surgery, Hanyang University College of Medicine, Seoul, Korea.
  • Kim S; Department of Public Health Sciences, Hanyang University College of Medicine, Seoul, Korea.
  • Choi JY; Department of Surgery, Hanyang University College of Medicine, Seoul, Korea.
  • Kim KS; Department of Surgery, Hanyang University College of Medicine, Seoul, Korea.
  • Jung YK; Department of Surgery, Hanyang University College of Medicine, Seoul, Korea.
  • Park B; Department of Preventive Medicine, Hanyang University College of Medicine, Seoul, Korea.
  • Choi D; Department of Surgery, Hanyang University College of Medicine, Seoul, Korea.
Br J Surg ; 111(4)2024 Apr 03.
Article em En | MEDLINE | ID: mdl-38637312
ABSTRACT

BACKGROUND:

Machine perfusion is an organ preservation strategy used to improve function over simple storage in a cold environment. This article presents an updated systematic review and meta-analysis of machine perfusion in deceased donor kidneys.

METHODS:

RCTs from November 2018 to July 2023 comparing machine perfusion versus static cold storage in kidney transplantation were evaluated for systematic review. The primary outcome in meta-analysis was delayed graft function.

RESULTS:

A total 19 studies were included, and 16 comparing hypothermic machine perfusion with static cold storage were analysed. The risk of delayed graft function was lower with hypothermic machine perfusion (risk ratio (RR) 0.77, 95% c.i. 0.69 to 0.86), even in kidneys after circulatory death (RR 0.78, 0.68 to 0.90) or brain death (RR 0.73, 0.63 to 0.84). Full hypothermic machine perfusion decreased the risk of delayed graft function (RR 0.69, 0.60 to 0.79), whereas partial hypothermic machine perfusion did not (RR 0.92, 0.69 to 1.22). Normothermic machine perfusion or short-term oxygenated hypothermic machine perfusion preservation after static cold storage was equivalent to static cold storage in terms of delayed graft function and 1-year graft survival.

CONCLUSION:

Hypothermic machine perfusion reduces delayed graft function risks and normothermic approaches show promise.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transplante de Rim / Função Retardada do Enxerto Limite: Humans Idioma: En Revista: Br J Surg Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transplante de Rim / Função Retardada do Enxerto Limite: Humans Idioma: En Revista: Br J Surg Ano de publicação: 2024 Tipo de documento: Article