Your browser doesn't support javascript.
loading
Antibiotic ciprofloxacin removal from aqueous solutions by electrochemically activated persulfate process: Optimization, degradation pathways, and toxicology assessment.
Yakamercan, Elif; Aygün, Ahmet; Simsek, Halis.
Afiliação
  • Yakamercan E; Environmental Engineering Department, Bursa Technical University, Bursa, Turkey.
  • Aygün A; Environmental Engineering Department, Bursa Technical University, Bursa, Turkey. Electronic address: ahmet.aygun@btu.edu.tr.
  • Simsek H; Agricultural and Biological Engineering Department, Purdue University, West Lafayette, IN, USA.
J Environ Sci (China) ; 143: 85-98, 2024 Sep.
Article em En | MEDLINE | ID: mdl-38644026
ABSTRACT
Ciprofloxacin (CIP) is a commonly used antibiotic in the fluoroquinolone group and is widely used in medical and veterinary medicine disciplines to treat bacterial infections. When CIP is discharged into the sewage system, it cannot be removed by a conventional wastewater treatment plant because of its recalcitrant characteristics. In this study, boron-doped diamond anode and persulfate were used to degrade CIP in an aquatic solution by creating an electrochemically activated persulfate (EAP) process. Iron was added to the system as a coactivator and the process was called EAP+Fe. The effects of independent variables, including pH, Fe2+, persulfate concentration, and electrolysis time on the system were optimized using the response surface methodology. The results showed that the EAP+Fe process removed 94% of CIP under the following optimum conditions A pH of 3, persulfate/Fe2+ concentration of 0.4 mmol/L, initial CIP concentration 30 mg/L, and electrolysis time of 12.64 min. CIP removal efficiency was increased from 65.10% to 94.35% by adding Fe2+ as a transition metal. CIP degradation products, 7 pathways, and 78 intermediates of CIP were studied, and three of those intermediates (m/z 298, 498, and 505) were reported. The toxicological analysis based on toxicity estimation software results indicated that some degradation products of CIP were toxic to targeted animals, including fathead minnow, Daphnia magna, Tetrahymena pyriformis, and rats. The optimum operation costs were similar in EAP and EAP+Fe processes, approximately 0.54 €/m3.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Ciprofloxacina / Antibacterianos Limite: Animals Idioma: En Revista: J Environ Sci (China) Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Ciprofloxacina / Antibacterianos Limite: Animals Idioma: En Revista: J Environ Sci (China) Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia