Your browser doesn't support javascript.
loading
Observation on the tilt and decentration of multifocal intraocular lens with optic capture in Berger space for pediatric cataract.
Fan, Zheng; Wang, Menghan; Peng, Yusu; Wang, Xiaoyun; Li, Dongfang; Ding, Yichao; Zhang, Jing; Huang, Yusen.
Afiliação
  • Fan Z; Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, Shandong, China.
  • Wang M; Hebei Eye Hospital, Xingtai, China.
  • Peng Y; Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, Shandong, China.
  • Wang X; Jiangsu Province Hospital, Nanjing, China.
  • Li D; Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, Shandong, China.
  • Ding Y; Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, Shandong, China.
  • Zhang J; Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, Shandong, China.
  • Huang Y; Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, Shandong, China.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Article em En | MEDLINE | ID: mdl-38671195
ABSTRACT

PURPOSE:

This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery.

METHODS:

This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively.

RESULTS:

All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively).

CONCLUSIONS:

The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier 1900023155).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Catarata / Extração de Catarata / Acuidade Visual / Lentes Intraoculares Multifocais Limite: Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: Int Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Catarata / Extração de Catarata / Acuidade Visual / Lentes Intraoculares Multifocais Limite: Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Revista: Int Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China