Your browser doesn't support javascript.
loading
Evaluating an extraction-free sample preparation method for multiplex detection of SARS-Cov-2, influenza A/B, and RSV with implementation on a microfluidic chip.
Ahmadi, Fatemeh; Zanganeh, Fatemeh Zahra; Amani Tehrani, Iman; Shoaee, Saeed; Choobin, Hamzeh; Bozorg, Ali; Taghipoor, Mojtaba.
Afiliação
  • Ahmadi F; Department of Biotechnology, College of Science, University of Tehran, Tehran, I.R., Iran.
  • Zanganeh FZ; Department of Biotechnology, College of Science, University of Tehran, Tehran, I.R., Iran.
  • Amani Tehrani I; Micro Nano System Laboratory (MNSL), Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
  • Shoaee S; Micro Nano System Laboratory (MNSL), Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
  • Choobin H; Department of Virology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
  • Bozorg A; Department of Biotechnology, College of Science, University of Tehran, Tehran, I.R., Iran.
  • Taghipoor M; Micro Nano System Laboratory (MNSL), Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran. Electronic address: mtaghipoor@sharif.ir.
Diagn Microbiol Infect Dis ; 109(3): 116325, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38688146
ABSTRACT
Following the relaxation of COVID-19 restrictions, other respiratory viruses such as influenza and respiratory syncytial virus (RSV), whose transmission were decreased due to COVID-19 precautions, are rising again. Because of similar clinical features and reported co-infections, multiplex detection of SARS-CoV-2, influenza A/B, and RSV is required to use specific treatments. This study assessed an extraction-free sample preparation (heat treatment at 95°C for 3 minutes) for multiplex detection using rRT-PCR. Despite an observed Ct-delay (∆Ct) averageing 1.26 compared to the standard method, an acceptable total sensitivity of 92 % and a negative predictive value (NPV) of 96 % were obtained. Moreover, Implementation on a microfluidic chip demonstrated efficiency, maintaining an excellent correlation (R2=0.983) with the standard method. Combining this extraction-free procedure with rRT-PCR on a microfluidic chip seems promising, because it simplifies the design and reduces the cost and complexity of the integrated assay for multiplex detection of SARS-CoV-2, influenza A/B, and RSV.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vírus da Influenza A / Vírus da Influenza B / Infecções por Vírus Respiratório Sincicial / Influenza Humana / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: Diagn Microbiol Infect Dis Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vírus da Influenza A / Vírus da Influenza B / Infecções por Vírus Respiratório Sincicial / Influenza Humana / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: Diagn Microbiol Infect Dis Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã