Your browser doesn't support javascript.
loading
Automated region growing-based segmentation for trabecular bone structure in fresh-frozen human wrist specimens.
Klintström, Eva; Klintström, Benjamin; Smedby, Örjan; Moreno, Rodrigo.
Afiliação
  • Klintström E; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, SE-58185, Sweden. eva.klintstrom@liu.se.
  • Klintström B; Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, SE-58185, Sweden. eva.klintstrom@liu.se.
  • Smedby Ö; Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden.
  • Moreno R; Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden.
BMC Med Imaging ; 24(1): 101, 2024 May 01.
Article em En | MEDLINE | ID: mdl-38693510
ABSTRACT
Bone strength depends on both mineral content and bone structure. Measurements of bone microstructure on specimens can be performed by micro-CT. In vivo measurements are reliably performed by high-resolution peripheral computed tomography (HR-pQCT) using dedicated software. In previous studies from our research group, trabecular bone properties on CT data of defatted specimens from many different CT devices have been analyzed using an Automated Region Growing (ARG) algorithm-based code, showing strong correlations to micro-CT.The aim of the study was to validate the possibility of segmenting and measuring trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens. Data from micro-CT was used as reference. The hypothesis was that the ARG-based in-house built software could be used for such measurements.HR-pQCT image data at two resolutions (61 and 82 µm isotropic voxels) from 23 fresh-frozen human forearms were analyzed. Correlations to micro-CT were strong, varying from 0.72 to 0.99 for all parameters except trabecular termini and nodes. The bone volume fraction had correlations varying from 0.95 to 0.98 but was overestimated compared to micro-CT, especially at the lower resolution. Trabecular separation and spacing were the most stable parameters with correlations at 0.80-0.97 and mean values in the same range as micro-CT.Results from this in vitro study show that an ARG-based software could be used for segmenting and measuring 3D trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens using micro-CT data as reference. Over-and underestimation of several of the bone structure parameters must however be taken into account.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Microtomografia por Raio-X / Osso Esponjoso Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Med Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Microtomografia por Raio-X / Osso Esponjoso Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Med Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Suécia