Your browser doesn't support javascript.
loading
Estimated Pulse Wave Velocity as a Novel Non-Invasive Biomarker for Metabolic Syndrome Among People Living with HIV.
Chen, Suling; Jiang, Yuanhui; Lin, Xiaoli; Chen, Hongjie; Wu, Xiaoxuan; Qian, Zhe; Xu, Xuwen; Zhong, Huiqun; Peng, Jie; Cai, Shaohang.
Afiliação
  • Chen S; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Jiang Y; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Lin X; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Chen H; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Wu X; Department of Communicable and Endemic Disease Control and Prevention, Haizhu District Center for Disease Control and Prevention, Guangzhou, People's Republic of China.
  • Qian Z; Second Department of Elderly Respiratory, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong Provincial Geriatrics Institute, Guangzhou, People's Republic of China.
  • Xu X; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Zhong H; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Peng J; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
  • Cai S; Department of Infectious Diseases, Nanfang Hospital, Southern Medical University, Guangzhou, People's Republic of China.
Diabetes Metab Syndr Obes ; 17: 1999-2010, 2024.
Article em En | MEDLINE | ID: mdl-38765471
ABSTRACT

Purpose:

This study aims to investigate the relationship between estimated pulse wave velocity (ePWV) and metabolic syndrome (MetS) in people living with HIV (PLWH), proposing a novel and convenient predictor for early detection of MetS in PLWH. Patients and

Methods:

A total of 485 PLWH were enrolled. These participants were categorized into two groups based on the estimated pulse wave velocity (ePWV) level. Demographic and clinical data were collected to investigate the correlation between ePWV and MetS.

Results:

The cohort of 485 PLWH was categorized into high-ePWV and low-ePWV groups based on ePWV cutoff value of 10 m/s. We observed significant differences in components of MetS including triglycerides (TG, P < 0.05), HDL cholesterol (HDL-C, P < 0.01), systolic blood pressure (SBP, P < 0.001), diastolic blood pressure (DBP, P < 0.05), and fasting plasma glucose (FPG, P < 0.001) between the two groups. Furthermore, we employed receiver operating characteristic (ROC) curves to demonstrate the effectiveness of ePWV as a predictive indicator for MetS in PLWH (AUC = 0.739, P < 0.001). According to the ROC curve, the optimal cut-off value of ePWV was 7.4 m/s, and its sensitivity and specificity in diagnosing MetS in PLWH were 79.03% and 64.07%, respectively. Although the 7.4 m/s cutoff increased the false positive rate compared to the traditional cutoff, it significantly reduced the rate of missed diagnoses, effectively identifying 79.03% of PLWH with MetS.

Conclusion:

ePWV is a non-invasive and convenient novel biomarker with predictive capabilities for MetS in PLWH.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Diabetes Metab Syndr Obes Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Diabetes Metab Syndr Obes Ano de publicação: 2024 Tipo de documento: Article