Your browser doesn't support javascript.
loading
The Effect of Different Electric Toothbrush Technologies on Interdental Plaque Removal: A Systematic Review with a Meta-Analysis.
Lewis, Robert David; Kanagasingam, Shalini; Cook, Neil; Krysmann, Marta; Taylor, Kathryn; Pisani, Flavio.
Afiliação
  • Lewis RD; School of Medicine and Dentistry, University of Central Lancashire, Preston PR1 2HE, UK.
  • Kanagasingam S; School of Medicine and Dentistry, University of Central Lancashire, Preston PR1 2HE, UK.
  • Cook N; School of Medicine and Dentistry, University of Central Lancashire, Preston PR1 2HE, UK.
  • Krysmann M; School of Medicine and Dentistry, University of Central Lancashire, Preston PR1 2HE, UK.
  • Taylor K; School of Medicine and Dentistry, University of Central Lancashire, Preston PR1 2HE, UK.
  • Pisani F; School of Medicine and Dentistry, University of Central Lancashire, Preston PR1 2HE, UK.
Healthcare (Basel) ; 12(10)2024 May 16.
Article em En | MEDLINE | ID: mdl-38786445
ABSTRACT
The removal of dental plaque from the gingival margins of the teeth is essential to maintaining periodontal health. Whilst it has been established that electric toothbrushes demonstrate a greater ability to remove plaque, no systematic review has specifically investigated which technology is better for removing plaque from the interdental tooth surfaces, where plaque control may be more difficult. Three databases were searched until October 2023 MEDLINE and DOSSS via EBSCOhost and Embase. Data extraction was carried out on studies which met the inclusion criteria, and a risk of bias assessment was completed. The study findings were combined via a narrative synthesis and a meta-analysis where appropriate. A total of 77 studies were found, out of which 14 were selected and included in the analysis. The mean difference in interproximal plaque reduction, measured using the Rustogi Modified Naval Plaque Index (RMNPI) at 8 weeks, was 0.09 (p < 0.00001) in favor of the oscillating-rotating toothbrush. At 6 and 12 weeks, the mean difference in plaque reduction (RMNPI) was 0.05 (p = 0.0008) and 0.04 (p = 0.0001) in favor of the oscillating-rotating toothbrush, respectively. The studies show a tendency for oscillating-rotating toothbrushes to remove more interproximal plaque than oscillating toothbrushes, especially in a short time (8 weeks).
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Healthcare (Basel) Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Healthcare (Basel) Ano de publicação: 2024 Tipo de documento: Article