Your browser doesn't support javascript.
loading
Application of Independent Component Analysis and Nelder-Mead Particle Swarm Optimization Algorithm in Non-Contact Blood Pressure Estimation.
Su, Te-Jen; Lin, Wei-Hong; Zhuang, Qian-Yi; Hung, Ya-Chung; Yang, Wen-Rong; He, Bo-Jun; Wang, Shih-Ming.
Afiliação
  • Su TJ; Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan.
  • Lin WH; Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan.
  • Zhuang QY; Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan.
  • Hung YC; Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan.
  • Yang WR; Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan.
  • He BJ; Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 80782, Taiwan.
  • Wang SM; Department of Computer Science and Information Engineering, Cheng Shiu University, Kaohsiung 833, Taiwan.
Sensors (Basel) ; 24(11)2024 May 30.
Article em En | MEDLINE | ID: mdl-38894333
ABSTRACT
In recent years, hypertension has become one of the leading causes of illness and death worldwide. Changes in lifestyle among the population have led to an increasing prevalence of hypertension. This study proposes a non-contact blood pressure estimation method that allows patients to conveniently monitor their blood pressure values. By utilizing a webcam to track facial features and the region of interest (ROI) for obtaining forehead images, independent component analysis (ICA) is employed to eliminate artifact signals. Subsequently, physiological parameters are calculated using the principle of optical wave reflection. The Nelder-Mead (NM) simplex method is combined with the particle swarm optimization (PSO) algorithm to optimize the empirical parameters, thus enhancing computational efficiency and accurately determining the optimal solution for blood pressure estimation. The influences of light intensity and camera distance on the experimental results are also discussed. Furthermore, the measurement time is only 10 s. The superior accuracy and efficiency of the proposed methodology are demonstrated by comparing them with those in other published literature.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pressão Sanguínea / Determinação da Pressão Arterial / Algoritmos Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pressão Sanguínea / Determinação da Pressão Arterial / Algoritmos Limite: Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Taiwan