Your browser doesn't support javascript.
loading
Comparing preprocessing strategies for 3D-Gene microarray data of extracellular vesicle-derived miRNAs.
Takemoto, Yuto; Ito, Daisuke; Komori, Shota; Kishimoto, Yoshiyuki; Yamada, Shinichiro; Hashizume, Atsushi; Katsuno, Masahisa; Nakatochi, Masahiro.
Afiliação
  • Takemoto Y; Public Health Informatics Unit, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-Minami, Higashi-Ku, Nagoya, 461-8673, Japan.
  • Ito D; Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
  • Komori S; Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
  • Kishimoto Y; Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
  • Yamada S; Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
  • Hashizume A; Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
  • Katsuno M; Department of Clinical Research Education, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
  • Nakatochi M; Department of Neurology, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya, 466-8550, Japan.
BMC Bioinformatics ; 25(1): 221, 2024 Jun 20.
Article em En | MEDLINE | ID: mdl-38902629
ABSTRACT

BACKGROUND:

Extracellular vesicle-derived (EV)-miRNAs have potential to serve as biomarkers for the diagnosis of various diseases. miRNA microarrays are widely used to quantify circulating EV-miRNA levels, and the preprocessing of miRNA microarray data is critical for analytical accuracy and reliability. Thus, although microarray data have been used in various studies, the effects of preprocessing have not been studied for Toray's 3D-Gene chip, a widely used measurement method. We aimed to evaluate batch effect, missing value imputation accuracy, and the influence of preprocessing on measured values in 18 different preprocessing pipelines for EV-miRNA microarray data from two cohorts with amyotrophic lateral sclerosis using 3D-Gene technology.

RESULTS:

Eighteen different pipelines with different types and orders of missing value completion and normalization were used to preprocess the 3D-Gene microarray EV-miRNA data. Notable results were suppressed in the batch effects in all pipelines using the batch effect correction method ComBat. Furthermore, pipelines utilizing missForest for missing value imputation showed high agreement with measured values. In contrast, imputation using constant values for missing data exhibited low agreement.

CONCLUSIONS:

This study highlights the importance of selecting the appropriate preprocessing strategy for EV-miRNA microarray data when using 3D-Gene technology. These findings emphasize the importance of validating preprocessing approaches, particularly in the context of batch effect correction and missing value imputation, for reliably analyzing data in biomarker discovery and disease research.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise de Sequência com Séries de Oligonucleotídeos / MicroRNAs / Vesículas Extracelulares Limite: Humans Idioma: En Revista: BMC Bioinformatics Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise de Sequência com Séries de Oligonucleotídeos / MicroRNAs / Vesículas Extracelulares Limite: Humans Idioma: En Revista: BMC Bioinformatics Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão