Introduction:
Various techniques and reinforcements have been proposed over the years in order to prevent leaks and bleeding after sleeve gastrectomy (LSG). The aim of this study was to retrospectively compare the staple line complication (SLC) rate in patients who underwent LSG with the use of bioabsorbable membrane (GORE® SEAMGUARD®, GoR) for staple line versus those who received no reinforcement.Methods:
Data on all consecutive patients undergoing LSG between 1 January 2014 and 31 December 2018 were retrospectively reviewed. Patients were divided into two groups the GoR+ group if the SeamGuard (GoR) was used and the GoR- group if no reinforcement was applied on the staple line. Preoperative demographics and rate of SLC were compared between groups. All cases of SLC coming from other centers were also reviewed.Results:
A total number of 626 LSGs were performed at our institution during the study period. GoR was applied in 450 (71.9%) cases (GoR+ group), while NR was used in 176 (28.1%) patients (GoR- group). Two (1.13%) cases of leaking and two (1.13%) cases of bleeding occurred in the GoR- group, while no SLC was recorded in patients who received GoR (p < 0.05). Thirteen cases of SLC coming from other institutions were treated at our hospital; all these cases were performed without any SLR.Conclusion:
In our case series, the use of GoR reduced the rate of SLC after LSG. In all cases of SLC coming from other institutions, no reinforcement had been applied on the staple line during LSG.