Development of an angle-adjustable photonic crystal fluorescence platform for sensitive detection of oxytetracycline.
Huang, Yunhuan; Zhang, Jiaheng; Sui, Bo; Chai, Guobi; Yu, Ajuan; Chen, Sheng; Zhang, Miaomiao; Zhang, Shusheng; Zhang, Yanhao; Zhao, Wuduo.
Afiliação
  • Huang Y; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Zhang J; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Sui B; Food Laboratory of Zhongyuan - Zhengzhou University, Luohe 462300, P. R. China.
  • Chai G; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Yu A; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Chen S; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Zhang M; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Zhang S; College of Chemistry, Zhengzhou University, Zhengzhou 450001, P. R. China.
  • Zhang Y; Food Laboratory of Zhongyuan - Zhengzhou University, Luohe 462300, P. R. China.
  • Zhao W; College of Ecology and Environment, Zhengzhou University, Zhengzhou 450001, P. R. China. zhaowuduo@163.com.
Chem Commun (Camb) ; 60(62): 8115-8118, 2024 Jul 30.
Article em En | MEDLINE | ID: mdl-38994726
ABSTRACT
We pioneered an angle-adjustable photonic crystal fluorescence platform (APC-Fluor) that integrates PCs, an angular resolution spectrometer and a strategically aligned laser source. This configuration, featuring a coaxial rotating swing arm, allows for precise control over the angles of incidence and emission. The presence of photonic crystal microcavities facilitates the dispersion of fluorescent materials and promotes the transition of electrons from the excited state to the lowest vibrational energy level. The optical resonance effect triggered by modulating the alignment of the reflection peaks of the photonic crystals with the emission peaks of the fluorescent materials can significantly enhance the fluorescence intensity. Compared with the single BSA-AuNCs, the optimized fluorescence intensity can be significantly increased by 11.9-fold. The APC-Fluor system showcases rapid and highly sensitive detection capabilities for oxytetracycline (OTC), exhibiting a response across a concentration range from 2 to 1 × 104 nM and achieving a notably low detection limit of 1.03 nM.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Chem Commun (Camb) Assunto da revista: QUIMICA Ano de publicação: 2024 Tipo de documento: Article