Your browser doesn't support javascript.
loading
Construction of UCNPs-aptamer-AuNPs luminescence energy transfer probe for ratio detection of Staphylococcus aureus.
Cheng, Juanjuan; Wei, Xinru; Wang, Lun; Chen, Hongqi.
Afiliação
  • Cheng J; Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, China.
  • Wei X; Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, China.
  • Wang L; Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, China.
  • Chen H; Anhui Province Key Laboratory of Biomedical Materials and Chemical Measurement, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, China.
Luminescence ; 39(7): e4829, 2024 Jul.
Article em En | MEDLINE | ID: mdl-39004775
ABSTRACT
A ratio luminescence probe was developed for detecting Staphylococcus aureus (S. aureus) based on luminescence energy transfer (LET) using double-wavelength emission (550 nm and 812 nm) upconversion nanoparticles (UCNPs) as donor, gold nanoparticles (AuNPs) as acceptor and the aptamer for S. aureus as the specific recognition and link unit. The LET process could cause luminescence quenching because of the spectral overlap between the acceptor and the donor at 550 nm. In the presence of S. aureus, S. aureus selectively combined with the aptamer, and the AuNPs left the surface of UCNPs, which weakened the quenching effect and restored the luminescence of UCNPs. Based on this, the ratio detection was realized by monitoring the change of the luminescence signal of the probe at 550 nm and taking the luminescence signal at 812 nm as the reference signal. Crucially, the probe has a fast reaction speed, with a reaction time of 25 min, and the detection of S. aureus is realized in the concentration range of 5.0 × 103-3.0 × 105 CFU/ml, with the detection limit of 106 CFU/ml. Therefore, the ratio probe has great potential for detecting of S. aureus in food because of its high sensitivity, fast speed and good selectivity.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Staphylococcus aureus / Luminescência / Transferência de Energia / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas / Ouro / Medições Luminescentes Idioma: En Revista: Luminescence Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Staphylococcus aureus / Luminescência / Transferência de Energia / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas / Ouro / Medições Luminescentes Idioma: En Revista: Luminescence Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China