Evaluation of time in tight range and the glycaemia risk index in adults with type 1 diabetes using an advanced hybrid closed loop system: A 1-year real-world assessment.
Rizzi, Alessandro; Tartaglione, Linda; Lucaccini Paoli, Lorenzo; Leo, Maria Laura; Popolla, Valentina; Viti, Luca; Barberio, Annarita; Di Leo, Mauro; Pontecorvi, Alfredo; Pitocco, Dario.
Afiliação
  • Rizzi A; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Tartaglione L; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Lucaccini Paoli L; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Leo ML; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Popolla V; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Viti L; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Barberio A; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Di Leo M; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Pontecorvi A; Department of Endocrinology, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
  • Pitocco D; Diabetes Care Unit, Fondazione Policlinico Agostino Gemelli, Universita' Cattolica del Sacro Cuore, Rome, Italy.
Diabetes Obes Metab ; 26(9): 4078-4086, 2024 Sep.
Article em En | MEDLINE | ID: mdl-39010292
ABSTRACT

AIM:

To assess the long-term glycaemic outcomes, with additional metrics, in adults with type 1 diabetes (T1D) using the Tandem tslim X2 with Control-IQ technology advanced hybrid closed-loop (AHCL) system.

METHODS:

This was a single-centre, retrospective study involving 56 T1D patients who transitioned to the Tandem tslim X2 with Control-IQ system. The primary and secondary endpoints consisted of variations in time in tight range (TiTR; 70-140 mg/dL) and the glycaemia risk index (GRI), respectively. Additional standardized continuous glucose monitoring (CGM) metrics, mean sensor glucose, coefficient of variation, the glucose management indicator (GMI), HbA1c and insulin daily dose, were also evaluated. Variables were measured at baseline and at 15 days, 3 months, 6 months and 1 year after Tandem tslim X2 Control-IQ initiation. Glucose outcomes are expressed as mean (standard deviation).

RESULTS:

Use of Tandem tslim X2 with Control-IQ over 1 year was associated with an increase in mean TiTR, from 38.11% (17.05%) to 43.10% (13.20%) (P = .059), and with a decline in the GRI, from 41.03 (25.48) to 28.55 (16.27) (P = .008). CGM metrics, including time in range and time above range, showed consistent improvements. Mean sensor glucose, the GMI and HbA1c decreased significantly over time. After an initial increase, insulin daily dose remained stable throughout the 12 months.

CONCLUSIONS:

The results highlight the sustained effectiveness of Tandem tslim X2 with Control-IQ in improving glycaemic outcomes over 1 year and support the use of this technology for the management of T1D.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glicemia / Sistemas de Infusão de Insulina / Automonitorização da Glicemia / Diabetes Mellitus Tipo 1 / Controle Glicêmico / Hipoglicemiantes / Insulina Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Diabetes Obes Metab Assunto da revista: ENDOCRINOLOGIA / METABOLISMO Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glicemia / Sistemas de Infusão de Insulina / Automonitorização da Glicemia / Diabetes Mellitus Tipo 1 / Controle Glicêmico / Hipoglicemiantes / Insulina Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Diabetes Obes Metab Assunto da revista: ENDOCRINOLOGIA / METABOLISMO Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália