Your browser doesn't support javascript.
loading
Detection and Evaluation for High-Quality CPR Based on Motion Capture Devices: A Preliminary Test.
Tang, Xingyi; Piao, Meihua; Wang, Yan; Ma, Haoming; Wang, Aoqi; Zhou, You; Li, Sijia; Pei, Runyuan.
Afiliação
  • Tang X; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Piao M; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Wang Y; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Ma H; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Wang A; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Zhou Y; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Li S; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
  • Pei R; School of Nursing, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
Stud Health Technol Inform ; 315: 145-149, 2024 Jul 24.
Article em En | MEDLINE | ID: mdl-39049242
ABSTRACT
High-quality cardiopulmonary resuscitation (CPR) is important for successful revival. This test aimed to accurately and effectively assess parameters in CPR operations, particularly focusing on the non-quantified arm posture, to assist instructors in guiding students to enhance the quality of their performance. We used motion capture system (Mars series, Nokov, China) to collect compression data from four trained students about five rounds of CPR, recording dynamic data of each marker in three-dimensional space following time. Using the processed data, we calculated compression depth, frequency, and arm angles. Their performance still needed improvement, and there were variations in data within individuals. This suggests that when instructors conduct assessments, they should focus on not only the overall performance but also each compression. This experiment provides a new perspective for quantifying compression parameters, and future efforts should continue to optimize and incorporate new parameters for assessment.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar Limite: Humans Idioma: En Revista: Stud Health Technol Inform Assunto da revista: INFORMATICA MEDICA / PESQUISA EM SERVICOS DE SAUDE Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Reanimação Cardiopulmonar Limite: Humans Idioma: En Revista: Stud Health Technol Inform Assunto da revista: INFORMATICA MEDICA / PESQUISA EM SERVICOS DE SAUDE Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China