Comparison of computer-assisted sperm analysis and smartphone-applied sperm analysis for evaluation of frozen-thawed bull semen.
Bastan, Ilktan.
Afiliação
  • Bastan I; Department of Reproduction and Artificial Insemination, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur, Turkey.
Reprod Domest Anim ; 59(8): e14695, 2024 Aug.
Article em En | MEDLINE | ID: mdl-39109457
ABSTRACT
This study aims to compare the efficacy of computer-assisted sperm analysis (CASA) and smartphone-applied sperm analysis (SASA) in assessing the quality of frozen-thawed bull semen. A total of 75 straws (n = 75) semen samples were used from different production batches of five Holstein bulls. The semen analyses were conducted in three groups Group I (CASA-37°C), semen samples were evaluated using the CASA system at 37°C (n = 25); Group II (SASA-25°C), semen samples were assessed using the SASA system at a temperature of room heat (25°C) (n = 25); and Group III (SASA-37°C), semen samples were evaluated using the SASA system at 37°C (n = 25). The frozen-thawed bull semen samples were analysed in terms of total motility (TM), progressive motility (PM), immotile, velocity average path (VAP), velocity curve linear (VCL), velocity straight line (VSL) and sperm concentration. There was no significant difference between the groups in terms of spermatozoa concentration (p > .05). However, significant differences among the groups were observed for total motile spermatozoa values (p < .001). Values of progressive motile spermatozoa were lower in Group I and Group II compared to Group III (p < .001). The immotile spermatozoa values were significant between the groups (p < .001) and were found to be proportional to total motile spermatozoa values. Additionally, the VAP, VCL and VSL values were comparable between Group II and Group III, but lower when compared to Group I. In conclusion, the results of the study demonstrate that the Sperm Cell™ system can accurately analyse the concentration of frozen-thawed bull semen. The analyses performed at room temperature indicate a parallelism between the PM value and CASA results. However, it is thought that SASA devices require a series of standardization studies in different semen extenders, different sample concentrations and different animal species, analogous to the standardization evolution process of CASA devices in semen analysis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Preservação do Sêmen / Motilidade dos Espermatozoides / Espermatozoides / Criopreservação / Análise do Sêmen / Smartphone Limite: Animals Idioma: En Revista: Reprod Domest Anim Assunto da revista: MEDICINA REPRODUTIVA / MEDICINA VETERINARIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Preservação do Sêmen / Motilidade dos Espermatozoides / Espermatozoides / Criopreservação / Análise do Sêmen / Smartphone Limite: Animals Idioma: En Revista: Reprod Domest Anim Assunto da revista: MEDICINA REPRODUTIVA / MEDICINA VETERINARIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia