Potential anatomical triggers for plan adaptation of cervical cancer external beam radiotherapy.
Brown, Rhianna; Holloway, Lois; Lau, Annie; Lim, Karen; Moodaley, Pereshin; Metcalfe, Peter; Do, Viet; Cutajar, Dean; Walker, Amy.
Afiliação
  • Brown R; Liverpool and Macarthur Cancer Therapy Centres, Sydney, NSW, Australia. rb672@uowmail.edu.au.
  • Holloway L; Ingham Institute of Applied Medical Research, Sydney, NSW, Australia. rb672@uowmail.edu.au.
  • Lau A; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia. rb672@uowmail.edu.au.
  • Lim K; Liverpool and Macarthur Cancer Therapy Centres, Sydney, NSW, Australia.
  • Moodaley P; Ingham Institute of Applied Medical Research, Sydney, NSW, Australia.
  • Metcalfe P; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.
  • Do V; South West Sydney Clinical Campuses, University of New South Wales, Sydney, NSW, Australia.
  • Cutajar D; Institute of Medical Physics, University of Sydney, Sydney, NSW, Australia.
  • Walker A; Liverpool and Macarthur Cancer Therapy Centres, Sydney, NSW, Australia.
Phys Eng Sci Med ; 2024 Aug 08.
Article em En | MEDLINE | ID: mdl-39115739
ABSTRACT
This study aimed to identify potential anatomical variation triggers using magnetic resonance imaging for plan adaption of cervical cancer patients to ensure dose requirements were met over an external beam radiotherapy course. Magnetic resonance images (MRIs) acquired before and during treatment were rigidly registered to a pre-treatment computerised tomography (CT) image for 11 retrospective cervix cancer datasets. Target volumes (TVs) and organs at risk (OARs) were delineated on both MRIs and propagated onto the CT. Treatment plans were generated based on the pre-treatment contours and applied to the mid-treatment contours. Anatomical and dosimetric changes between each timepoint were assessed. The anatomical changes included the change in centroid position and volume size. Dosimetric changes included the V30Gy and V40Gy for the OARs, and V95%, V100%, D95% and D98% for the TVs. Correlation with dosimetric and anatomical changes were assessed to determine potential replan triggers. Changes in the bowel volume and position in the superior-inferior direction, and the high-risk CTV anterior posterior position were highly correlated with a change in dose to the bowel and target, respectively. Hence changes in bowel and high-risk CTV could be used as a potential replan triggers.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Phys Eng Sci Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: Phys Eng Sci Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália