Your browser doesn't support javascript.
loading
Effects of organ dose modulation applied to a part of the scan range on radiation dose in computed tomography of the body.
Inoue, Yusuke; Itoh, Hiroyasu; Koizumi, Koji; Sekimoto, Saori; Hata, Hirofumi; Miyatake, Hiroki; Yamane, Takuro; Mitsui, Kohei.
Afiliação
  • Inoue Y; Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Kanagawa, Japan.
  • Itoh H; Department of Radiology, Kitasato University Hospital, Sagamihara 252-0375, Kanagawa, Japan.
  • Koizumi K; Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Kanagawa, Japan.
  • Sekimoto S; Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Kanagawa, Japan.
  • Hata H; Department of Radiology, Kitasato University Hospital, Sagamihara 252-0375, Kanagawa, Japan.
  • Miyatake H; Department of Radiology, Kitasato University Hospital, Sagamihara 252-0375, Kanagawa, Japan.
  • Yamane T; Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Kanagawa, Japan.
  • Mitsui K; Department of Radiology, JCHO Sagamino Hospital, 1-2-30 Fuchinobe, Chuo-ku, Sagamihara, Kanagawa, Japan.
J Radiol Prot ; 44(3)2024 Aug 22.
Article em En | MEDLINE | ID: mdl-39121874
ABSTRACT
In computed tomography (CT), organ dose modulation (ODM) reduces radiation exposure from the anterior side to reduce radiation dose received by the radiosensitive organs located anteriorly. We investigated the effects of ODM applied to a part of the scan range on radiation dose in body CT. The thorax and thoraco-abdominopelvic region of an anthropomorphic whole-body phantom were imaged with and without ODM. ODM was applied to various regions, and the tube current modulation curves were compared. Additionally, the dose indices were compared with and without ODM in thoracic and thoraco-abdominopelvic CTs in 800 patients. ODM was applied to the thyroid in male patients and to the thyroid and breast in female patients. In phantom imaging of the thorax, the application of ODM below the scan range decreased the tube current, and that to the breast showed a further decrease. Decreased tube current was also observed in phantom imaging of the thoraco-abdominopelvic regions with ODM below the scan range, and the application of ODM to the whole scan range, thyroid, breast, and both thyroid and breast further reduced the tube current in the region to which ODM was applied. In patient imaging, the dose indices were significantly lower with ODM than without ODM, regardless of the scan range or sex. The absolute reduction in dose-length product was larger for thoraco-abdominopelvic CT (male, 43.2 mGy cm; female, 59.7 mGy cm) than for thoracic CT (male, 30.8 mGy cm; female, 37.6 mGy cm) in both sexes, indicating dose reduction in the abdominopelvic region to which ODM was not applied. In conclusion, The application of ODM in body CT reduces radiation dose not only in the region to which ODM is applied but also outside the region. In radiation dose management, it should be considered that even ODM applied to a limited region affects the dose indices.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Imagens de Fantasmas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Radiol Prot Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Tomografia Computadorizada por Raios X / Imagens de Fantasmas Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Radiol Prot Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão