Preparation of dicationic ionic liquid modified silica stationary phase for mixed-mode liquid chromatography and its application for food additive detection.
Anal Chim Acta
; 1321: 343018, 2024 Sep 08.
Article
em En
| MEDLINE
| ID: mdl-39155102
ABSTRACT
BACKGROUND:
Food safety has become an essential aspect of public concern and there are lots of detection means. Liquid chromatography plays a dominating role in food safety inspection because of its high separation efficiency and reproducibility. However, with the increasing complexity of real samples and monitoring requirements, conventional single-mode chromatography would require frequent column replacement and cannot separate different kinds of analytes on a single column simultaneously, which is costly and time-consuming. There is a great need for fabricating mixed-mode stationary phases and validating the feasibility of employing mixed-mode stationary phases for food safety inspection.RESULTS:
This work fabricated multifunctional stationary phases for liquid chromatography to determine diverse food additives under the mixed mode of RPLC/HILIC/IEC. Two dicationic ionic liquid silanes were synthesized and bonded onto the silica gel surface. The functionalized silica was characterized by Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and elemental analysis. Both columns provide satisfactory separation performance towards 6 hydrophilic nucleosides, 4 hydrophobic polycyclic aromatic hydrocarbons, and 5 anions. Great repeatability of retention (RSD <0.1 %) and column efficiency (100330 plate/m) were obtained. Thermomechanical analysis and linear solvation energy relationship investigated the retention mechanism. Finally, the better in two prepared columns was employed to separate and determine the contents of NO2- and NO3- in vegetables(highest 4906 mg kg-1 NO3- in spinach), preservatives in bottled beverages (180.8 mg kg-1 sodium benzoate in soft drink), and melamine in milk with satisfactory performance and recovery rates ranging from 96.4 % to 105.6 %.SIGNIFICANCE:
This work developed a novel scheme for preparing mixed-mode stationary phases by dicationic ionic liquid which provides great separation selectivity. Most importantly, this work proved the superiority of employing mixed-mode stationary phases for food safety inspection, which might avoid high-cost and frequent changes of columns and chromatography systems in the near future.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Dióxido de Silício
/
Líquidos Iônicos
/
Aditivos Alimentares
Idioma:
En
Revista:
Anal Chim Acta
Ano de publicação:
2024
Tipo de documento:
Article