Nitazene test strips: a laboratory evaluation.
Harm Reduct J
; 21(1): 159, 2024 Aug 28.
Article
em En
| MEDLINE
| ID: mdl-39198843
ABSTRACT
BACKGROUND:
2-Benzylbenzimidazole 'nitazene' opioids pose a growing threat to public health. Nitazene analogues are increasingly found mixed with or (mis)sold as heroin and in falsified (non-)opioid medications, posing a great risk of intoxication in users (un)knowingly exposed to these potent opioids. Lateral flow immunoassay nitazene test strips (NTS; BTNX Rapid Response™) became commercially available in Q1 2024, with the aim to enable rapid detection of nitazene analogues in drug samples. As only limited independent data is available on the performance of these strips, this lab-based study aimed at evaluating their potential for drug checking applications.METHODS:
Following dilution of drug standards in water, the NTS readouts were analyzed independently by two individuals and by ImageJ. The limit of detection for isotonitazene was determined using two manufacturing lots of NTS. Cross-reactivity with 32 other nitazene analogues was evaluated. Six sourced drug samples were tested to explore the ability of NTS to detect the presence of a nitazene analogue in authentic samples.RESULTS:
The limits of detection for isotonitazene were 2000 or 3000 ng/mL, depending on the lot. Twenty-four of the 33 tested nitazene analogues cross-reacted with the NTS at concentrations ≤ 9000 ng/mL. Structural analysis indicated that either substitution or removal of the 5-nitro group, or lengthening the linker between the two aromatic rings, generally hampered detection. All six authentic drug samples consistently tested positive, with no observed false negatives.CONCLUSIONS:
This study provides a better understanding of the potential of NTS for drug checking purposes. Our findings indicate that NTS can theoretically alert to the presence of most nitazene analogues that have emerged on recreational drug markets. However, 'desnitazenes' (lacking the 5-nitro group) may yield false negative results due to low cross-reactivity. Although factors like specificity, lot-to-lot variability, nitazene analogue content in drug samples, solubility, and different testing conditions should be considered, our study results indicate that, at least under the conditions evaluated here (using reference standards and sourced powders), NTS are capable of detecting the presence of a wide range of nitazene analogues. Hence, NTS may alert users of the presence of nitazene analogues in drug samples.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Nitrocompostos
Limite:
Humans
Idioma:
En
Revista:
Harm Reduct J
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Bélgica