Ductus arteriosus rupture as a balloon catheter atrioseptostomy complication.
Caixeta, A M; Kajita, L J; Rati, M; Assis, R V; Aiello, V; Snitcowsky, R; Perin, M A; Veloso, W U; Ariê, S.
Afiliação
  • Caixeta AM; Catheterization Laboratory of InCor, University of São Paulo, Brazil.
Cathet Cardiovasc Diagn ; 34(1): 48-51, 1995 Jan.
Article em En | MEDLINE | ID: mdl-7728853
ABSTRACT
A newborn with transposition of the great arteries presented with rupture of the ductus arteriosus after balloon catheter atrioseptostomy. The necropsy study demonstrated persistent ductus patency, and a 0.5-cm-long horizontal fissure could be observed. On microscopy, there was laceration of the intimal layer, with wall dissection and focal hemorrhage extending to the adventitia. Ductus rupture was attributed to the wall weakness, as a consequence of prostaglandin E1 administration.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Ruptura Aórtica / Transposição dos Grandes Vasos / Cateterismo / Canal Arterial Tipo de estudo: Diagnostic_studies Limite: Humans / Male / Newborn Idioma: En Revista: Cathet Cardiovasc Diagn Ano de publicação: 1995 Tipo de documento: Article País de afiliação: Brasil
Buscar no Google
Base de dados: MEDLINE Assunto principal: Ruptura Aórtica / Transposição dos Grandes Vasos / Cateterismo / Canal Arterial Tipo de estudo: Diagnostic_studies Limite: Humans / Male / Newborn Idioma: En Revista: Cathet Cardiovasc Diagn Ano de publicação: 1995 Tipo de documento: Article País de afiliação: Brasil